Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter.

The aim is to evaluate the agreement and accuracy of refraction using a binocular wavefront optometer with the autorefractor and phoropter. To do this, 1 month after corneal refractive surgery, the right eyes of 125 subjects were enrolled in this cross-sectional study. Objective and subjective refractions were measured using a binocular wavefront optometer, an autorefractor, and a phoropter in a noncycloplegic condition. The differences and agreement of refractive data were analyzed using the Wilcoxon signed-rank test and Bland-Altman plots. The differences between sphere (Z=-0.872, p=0.38), J0 (Z=-0.065, p=0.95), J45 (Z=-1.199, p=0.23), and SE (Z=-1.316, p=0.19), objectively detected by binocular wavefront optometer and autorefractor, were not statistically significant. The differences between J0 (Z=-0.533, p=0.59), J45 (Z=-0.724, p=0.47), and SE (Z=-0.933, p=0.35), subjectively detected by binocular wavefront optometer and phoropter, were not statistically significant, whereas sphere (Z=-3.699, p<0.0001) had statistically significant differences. The Bland-Altman plots showed agreement between binocular wavefront optometer objective refraction and autorefractor in sphere (95% LoA: -1.00 D to 0.89 D), J0 (95% LoA: -0.47 D to 0.47 D), J45 (95% LoA: -0.55 D to 0.58 D), and SE (95% LoA: -0.89 D to 0.96 D). The Bland-Altman plots also showed agreement between binocular wavefront optometer subjective refraction and phoropter in sphere (95% LoA: -0.59 D to 0.82 D), J0 (95% LoA: -0.47 D to 0.43 D), J45 (95% LoA: -0.47 D to 0.43 D), and SE (95% LoA: -0.66 D to 0.74 D). Conclusively, the binocular wavefront optometer is an effective instrument, demonstrating good agreement between its objective and subjective refraction results and those obtained from autorefractor and phoropter, its smaller refractive intervals presenting a high accuracy in refractive error detection.

Authors

Institutions

Publication Details

Journal
PubMed
Published
2025-09-16
DOI
https://doi.org/10.3791/68422
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter.

S. Xian, Peng Ji, Yifan Tang, Qingbao Wang et al.
PubMed
Ophthalmology and Visual Impairment Studies
article

Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter.

S. Xian, Peng Ji, Yifan Tang, Qingbao Wang, Li Li, Xiaofan Wang, Hongsheng Bi
article en

Abstract

The aim is to evaluate the agreement and accuracy of refraction using a binocular wavefront optometer with the autorefractor and phoropter. To do this, 1 month after corneal refractive surgery, the right eyes of 125 subjects were enrolled in this cross-sectional study. Objective and subjective refractions were measured using a binocular wavefront optometer, an autorefractor, and a phoropter in a noncycloplegic condition. The differences and agreement of refractive data were analyzed using the Wilcoxon signed-rank test and Bland-Altman plots. The differences between sphere (Z=-0.872, p=0.38), J0 (Z=-0.065, p=0.95), J45 (Z=-1.199, p=0.23), and SE (Z=-1.316, p=0.19), objectively detected by binocular wavefront optometer and autorefractor, were not statistically significant. The differences between J0 (Z=-0.533, p=0.59), J45 (Z=-0.724, p=0.47), and SE (Z=-0.933, p=0.35), subjectively detected by binocular wavefront optometer and phoropter, were not statistically significant, whereas sphere (Z=-3.699, p<0.0001) had statistically significant differences. The Bland-Altman plots showed agreement between binocular wavefront optometer objective refraction and autorefractor in sphere (95% LoA: -1.00 D to 0.89 D), J0 (95% LoA: -0.47 D to 0.47 D), J45 (95% LoA: -0.55 D to 0.58 D), and SE (95% LoA: -0.89 D to 0.96 D). The Bland-Altman plots also showed agreement between binocular wavefront optometer subjective refraction and phoropter in sphere (95% LoA: -0.59 D to 0.82 D), J0 (95% LoA: -0.47 D to 0.43 D), J45 (95% LoA: -0.47 D to 0.43 D), and SE (95% LoA: -0.66 D to 0.74 D). Conclusively, the binocular wavefront optometer is an effective instrument, demonstrating good agreement between its objective and subjective refraction results and those obtained from autorefractor and phoropter, its smaller refractive intervals presenting a high accuracy in refractive error detection.

PubMed(223)
Shandong University of Traditional Chinese Medicine (CN), Shandong Shierming Eye Hospital (CN)
Openalex Percentile: Top 65%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.