Screen-printed Potentiometric Selective Electrode Based on an Ammonium Quaternary Salt for Nitrate Detection

In this study, a screen-printed electrode for nitrate ions was evaluated with a selective membrane based on tetradecyl ammonium nitrate as the ionophore, o-nitrophenyl octyl ether as the plasticizer, and polyvinyl chloride as the polymeric matrix. The electrodes were printed on polyethylene terephthalate sheets using a screen-printing frame with the electrode template. Then, the selective membrane was deposited by drop casting. The principal analytical parameters were determined by the method of additions recommended by IUPAC. The membrane showed a good linear response range of 5.38 × 10−6 to 1 × 10−2 mol/L, being Nernstian according to the slope of −57.13 mV/dec (theoretical slope: −59.16 mV/dec), with a practical detection limit of 2.96 × 10−6 mol/L and a lower limit of linear response of 5.38 × 10−6 mol/L. The potentiometric selectivity coefficients for Cl−, Br−, I−, SO42−, and IO3− ions were determined using the mixed solutions method. The Br− ion was found to be the most relevant interferent. The electrode showed a fast stable response (20 s), as well as the possibility of use in a wide pH range (3–12) without compromising the potentiometric response.

Authors

Institutions

Publication Details

Journal
Periodica Polytechnica Chemical Engineering
Published
2025-09-18
DOI
https://doi.org/10.3311/ppch.41155
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Screen-printed Potentiometric Selective Electrode Based on an Ammonium Quaternary Salt for Nitrate Detection

Leodanis Correa Fajardo, Abel Ibrahim Balbín Tamayo, María de los Ángeles Arada Pérez, Javier Ernesto Vilasó-Cadre et al.
Periodica Polytechnica Chemical Engineering
Analytical Chemistry and Sensors
article

Screen-printed Potentiometric Selective Electrode Based on an Ammonium Quaternary Salt for Nitrate Detection

Leodanis Correa Fajardo, Abel Ibrahim Balbín Tamayo, María de los Ángeles Arada Pérez, Javier Ernesto Vilasó-Cadre, Ana Rosa Lazo Fraga, Karina Cardero Segura
article en

Abstract

In this study, a screen-printed electrode for nitrate ions was evaluated with a selective membrane based on tetradecyl ammonium nitrate as the ionophore, o-nitrophenyl octyl ether as the plasticizer, and polyvinyl chloride as the polymeric matrix. The electrodes were printed on polyethylene terephthalate sheets using a screen-printing frame with the electrode template. Then, the selective membrane was deposited by drop casting. The principal analytical parameters were determined by the method of additions recommended by IUPAC. The membrane showed a good linear response range of 5.38 × 10−6 to 1 × 10−2 mol/L, being Nernstian according to the slope of −57.13 mV/dec (theoretical slope: −59.16 mV/dec), with a practical detection limit of 2.96 × 10−6 mol/L and a lower limit of linear response of 5.38 × 10−6 mol/L. The potentiometric selectivity coefficients for Cl−, Br−, I−, SO42−, and IO3− ions were determined using the mixed solutions method. The Br− ion was found to be the most relevant interferent. The electrode showed a fast stable response (20 s), as well as the possibility of use in a wide pH range (3–12) without compromising the potentiometric response.

Periodica Polytechnica Chemical Engineering
Autonomous University of San Luis Potosí (MX), Universidad de Oriente (CU), University of Havana (CU)
Universidad de La Habana
Openalex Percentile: Top 66%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Screen-printed Potentiometric Selective Electrode Based on an Ammonium Quaternary Salt for Nitrate Detection — Leodanis Correa Fajardo, Abel Ibrahim Balbín Tamayo, et al. · Periodica Polytechnica Chemical Engineering (2025) | TGRS Research Map | TGRS