Post-tensioned concrete inspection and imaging using 2D and 3D Dry Point Contact ultrasound array
Evaluating the concrete quality by means of ultrasound inspection is a common NDT method utilized frequently by the asset owners. Advancements were introduced to the method by distributing numerous shear horizontal Dry Point Contact (DPC) transducers in a uniform way, forming a linear array that allows for immediate two-dimensional imaging of the subsurface using Synthetic Aperture Focusing Technique (SAFT). Recent developments were implemented, allowing for the full potential use of the array by means of three-dimensional data acquisition instead of two-dimensional. This work provides a practical comparison between the 2D Linear scanning mode and the newly introduced 3D Matrix scanning mode regarding the tendon duct inspection, grouting quality, and reinforcement localization. Imaging the subsurface was performed through research-oriented software, namely InterSAFT, which allows for 2D and 3D imaging using Linear and Matrix data acquisitions.
Authors
- Claudio Mazzotti (ORCID: https://orcid.org/0000-0002-5314-4687)
- Ernst Niederleithinger (ORCID: https://orcid.org/0000-0002-2501-2249)
- Nzeeh Roumia
Publication Details
- Journal
- e-Journal of Nondestructive Testing
- Published
- 2025-09-18
- DOI
- https://doi.org/10.58286/31690
- Citations
- 1
- Primary Topic
- Geophysical Methods and Applications
- Type
- article
- Field-Weighted Citation Impact
- 1.15