Impact of Saturation and Frequency of AC Voltage on Impedance and Piezoresistive Response of Self-Sensing Concrete for Structural Health Monitoring (SHM)

Self-sensing concrete (SSC) has emerged as a promising material for Structural Health Monitoring (SHM) due to its ability to detect internal strain and damage through its intrinsic electrical properties. This study investigates the combined influence of saturation and alternating current (AC) frequency on the impedance and piezoresistive behavior of SSC. The specimens were prepared using conductive steel fibers (CSF). Impedance and stress-resistivity measurements were conducted across a range of AC frequencies. Results indicate that drying significantly affects both impedance magnitude and phase angle, with more pronounced effects observed at higher frequencies. Additionally, the piezoresistive response of SSC exhibited strong frequency dependence. These findings highlight the importance of accounting for environmental factors and input in the design and implementation of SSC-based SHM systems. The study provides data analysis for optimizing measurement protocols to enhance the sensitivity and accuracy of self-sensing materials in real applications.

Authors

Publication Details

Journal
e-Journal of Nondestructive Testing
Published
2025-09-18
DOI
https://doi.org/10.58286/31734
Primary Topic
Smart Materials for Construction
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Saturation and Frequency of AC Voltage on Impedance and Piezoresistive Response of Self-Sensing Concrete for Structural Health Monitoring (SHM)

Ali Fattah, Shaban Shahzad, Mohammed Ali Al-Osta, Saeed Busubul
e-Journal of Nondestructive Testing
Smart Materials for Construction
article

Impact of Saturation and Frequency of AC Voltage on Impedance and Piezoresistive Response of Self-Sensing Concrete for Structural Health Monitoring (SHM)

Ali Fattah, Shaban Shahzad, Mohammed Ali Al-Osta, Saeed Busubul
article en

Abstract

Self-sensing concrete (SSC) has emerged as a promising material for Structural Health Monitoring (SHM) due to its ability to detect internal strain and damage through its intrinsic electrical properties. This study investigates the combined influence of saturation and alternating current (AC) frequency on the impedance and piezoresistive behavior of SSC. The specimens were prepared using conductive steel fibers (CSF). Impedance and stress-resistivity measurements were conducted across a range of AC frequencies. Results indicate that drying significantly affects both impedance magnitude and phase angle, with more pronounced effects observed at higher frequencies. Additionally, the piezoresistive response of SSC exhibited strong frequency dependence. These findings highlight the importance of accounting for environmental factors and input in the design and implementation of SSC-based SHM systems. The study provides data analysis for optimizing measurement protocols to enhance the sensitivity and accuracy of self-sensing materials in real applications.

e-Journal of Nondestructive TestingVol. 30(10)
Openalex Percentile: Top 81%
Smart Materials for Construction
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Impact of Saturation and Frequency of AC Voltage on Impedance and Piezoresistive Response of Self-Sensing Concrete for Structural Health Monitoring (SHM) — Ali Fattah, Shaban Shahzad, et al. · e-Journal of Nondestructive Testing (2025) | TGRS Research Map | TGRS