Translational Evaluation of an Intraparenchymal Collagen Matrix Tamponade: Initial Preclinical and Clinical Experiments to Prevent CSF Reflux Following Endoscopic Brain Surgery

Transparent polymer sheaths are often utilized in neuroendoscopic procedures to minimize intraventricular bleeding and parenchymal injuries. However, cerebrospinal fluid (CSF) leakage remains a common complication following neuroendoscopic surgery for intraventricular and deep-seated lesions. We investigated an innovative technique to prevent postoperative CSF leakage through the tract using a collagen matrix dural graft. A rolled collagen matrix (DuraGen<sup>®</sup>) was used as a parenchymal tract tamponade to seal the tract created by an angiocatheter (preclinical pilot) or neuroendoscopic sheath (clinical case studies). A small pilot study using a juvenile pig model was first conducted to test the implantation technique and to evaluate the inflammatory response to, and absorption of intraparenchymal DuraGen. The efficacy of this approach was then assessed in two clinical cases using MRI at postoperative days 1, 7, 40, and 60. The outer segment of the graft was unfurled to cover the dural defect for clinical application. In the pig model, histological analysis showed healing with minimal inflammation in DuraGen<sup>®</sup>-implanted hemispheres, while untreated control tracts exhibited parenchymal scarring and chronic inflammation. In both patients, postoperative MRI demonstrated resolution of subdural fluid collections and progressive absorption of DuraGen<sup>®</sup> with no complications. This technique ameliorated CSF leakage and enhanced parenchymal healing after neuroendoscopic surgery. DuraGen<sup>®</sup> may modulate the local environment for tissue repair beyond its use in dural grafting.

Authors

Institutions

Publication Details

Journal
International Journal of Molecular Sciences
Published
2025-09-18
DOI
https://doi.org/10.3390/ijms26189081
Citations
1
Primary Topic
Cerebrospinal fluid and hydrocephalus
Type
article
Field-Weighted Citation Impact
0.91
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Translational Evaluation of an Intraparenchymal Collagen Matrix Tamponade: Initial Preclinical and Clinical Experiments to Prevent CSF Reflux Following Endoscopic Brain Surgery

John C. O’Donnell, Kevin D. Browne, Takakazu Kawamata, Kentaro Chiba et al.
1 citations
International Journal of Molecular Sciences
Cerebrospinal fluid and hydrocephalus
0.91
article

Translational Evaluation of an Intraparenchymal Collagen Matrix Tamponade: Initial Preclinical and Clinical Experiments to Prevent CSF Reflux Following Endoscopic Brain Surgery

John C. O’Donnell, Kevin D. Browne, Takakazu Kawamata, Kentaro Chiba, Dmitriy Petrov, Yasuo Aihara, Yuichi Oda
article en
1 citations

Abstract

Transparent polymer sheaths are often utilized in neuroendoscopic procedures to minimize intraventricular bleeding and parenchymal injuries. However, cerebrospinal fluid (CSF) leakage remains a common complication following neuroendoscopic surgery for intraventricular and deep-seated lesions. We investigated an innovative technique to prevent postoperative CSF leakage through the tract using a collagen matrix dural graft. A rolled collagen matrix (DuraGen<sup>®</sup>) was used as a parenchymal tract tamponade to seal the tract created by an angiocatheter (preclinical pilot) or neuroendoscopic sheath (clinical case studies). A small pilot study using a juvenile pig model was first conducted to test the implantation technique and to evaluate the inflammatory response to, and absorption of intraparenchymal DuraGen. The efficacy of this approach was then assessed in two clinical cases using MRI at postoperative days 1, 7, 40, and 60. The outer segment of the graft was unfurled to cover the dural defect for clinical application. In the pig model, histological analysis showed healing with minimal inflammation in DuraGen<sup>®</sup>-implanted hemispheres, while untreated control tracts exhibited parenchymal scarring and chronic inflammation. In both patients, postoperative MRI demonstrated resolution of subdural fluid collections and progressive absorption of DuraGen<sup>®</sup> with no complications. This technique ameliorated CSF leakage and enhanced parenchymal healing after neuroendoscopic surgery. DuraGen<sup>®</sup> may modulate the local environment for tissue repair beyond its use in dural grafting.

International Journal of Molecular SciencesVol. 26(18)
Tokyo Women's Medical University (JP), University of Pennsylvania (US)
Openalex Percentile: Top 22%
Cerebrospinal fluid and hydrocephalus
0.91
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.