Comparative Assessment of Different Electrode Combinations for Phosphate Removal from Onsite Wastewater via Electrocoagulation

Phosphorus (P) discharge from onsite wastewater treatment systems (OWTSs) poses a significant threat to water quality, contributing to eutrophication in nutrient-sensitive aquatic environments. In treated effluents, P predominantly exists as orthophosphate (PO43−), a highly bioavailable and reactive form that requires targeted removal. This study evaluates the performance of electrocoagulation (EC) as a polishing step for PO43− removal from OWTS effluents using 12 anode/cathode combinations comprising aluminum (Al), iron (Fe), magnesium (Mg), and stainless steel (SS). Key operational parameters, including treatment time, mixing speed, current density, pH, and initial PO43− concentration, were systematically investigated when synthetic denitrified effluent (20 mg P/L) was treated. Based on the performance, the four most effective electrode combinations (Al/Al, Al/Mg, Fe/Al, and Mg/Mg), along with a commercial benchmark (Fe/Fe), were further tested under extended hydraulic retention times (up to 48 h) in both synthetic and real (denitrified) wastewater. To date, none of the studies have systematically evaluated all possible anode/cathode combinations involving multiple electrode materials under uniform operational conditions. The Al/Al and Mg/Mg EC systems achieved rapid and high PO43− removal efficiencies (>95%), while Mg-based systems demonstrated sustained performance over prolonged treatment durations, especially in real wastewater. Bimetallic pairs such as Al/Mg and Fe/Al exhibited synergistic effects through enhanced coagulant generation and pH stabilization. The results indicated that PO43− removal efficiency was strongly influenced by electrode material selection, hydrodynamic conditions, and wastewater compositions, underscoring the need to design EC systems based on site-specific water quality conditions in OWTSs.

Authors

Institutions

Publication Details

Journal
Water
Published
2025-09-18
DOI
https://doi.org/10.3390/w17182764
Primary Topic
Advanced oxidation water treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Assessment of Different Electrode Combinations for Phosphate Removal from Onsite Wastewater via Electrocoagulation

Xiumei Jian, Xinwei Mao, Arif Reza, Fanjian Zeng
Water
Advanced oxidation water treatment
article

Comparative Assessment of Different Electrode Combinations for Phosphate Removal from Onsite Wastewater via Electrocoagulation

Xiumei Jian, Xinwei Mao, Arif Reza, Fanjian Zeng
article en

Abstract

Phosphorus (P) discharge from onsite wastewater treatment systems (OWTSs) poses a significant threat to water quality, contributing to eutrophication in nutrient-sensitive aquatic environments. In treated effluents, P predominantly exists as orthophosphate (PO43−), a highly bioavailable and reactive form that requires targeted removal. This study evaluates the performance of electrocoagulation (EC) as a polishing step for PO43− removal from OWTS effluents using 12 anode/cathode combinations comprising aluminum (Al), iron (Fe), magnesium (Mg), and stainless steel (SS). Key operational parameters, including treatment time, mixing speed, current density, pH, and initial PO43− concentration, were systematically investigated when synthetic denitrified effluent (20 mg P/L) was treated. Based on the performance, the four most effective electrode combinations (Al/Al, Al/Mg, Fe/Al, and Mg/Mg), along with a commercial benchmark (Fe/Fe), were further tested under extended hydraulic retention times (up to 48 h) in both synthetic and real (denitrified) wastewater. To date, none of the studies have systematically evaluated all possible anode/cathode combinations involving multiple electrode materials under uniform operational conditions. The Al/Al and Mg/Mg EC systems achieved rapid and high PO43− removal efficiencies (>95%), while Mg-based systems demonstrated sustained performance over prolonged treatment durations, especially in real wastewater. Bimetallic pairs such as Al/Mg and Fe/Al exhibited synergistic effects through enhanced coagulant generation and pH stabilization. The results indicated that PO43− removal efficiency was strongly influenced by electrode material selection, hydrodynamic conditions, and wastewater compositions, underscoring the need to design EC systems based on site-specific water quality conditions in OWTSs.

WaterVol. 17(18)
Stony Brook University (US)
Openalex Percentile: Top 76%
Advanced oxidation water treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparative Assessment of Different Electrode Combinations for Phosphate Removal from Onsite Wastewater via Electrocoagulation — Xiumei Jian, Xinwei Mao, et al. · Water (2025) | TGRS Research Map | TGRS