Validation of an Reverse Phase High Performance Liquid Chromatography Method for <i>In Vitro</i> Quantification and Degradation Analysis of Naphthol AS-E Phosphate in Bulk Drugs and Nanoparticles

<i>This study presents the first validated High-performance liquid chromatography (HPLC) technique for quantifying naphthol AS-E phosphate (NASEP) in bulk drugs and nanoparticle formulation. A C18 HPLC cartridge (250 × 4.6 mm, 5 µm particle size) served as the stationary phase for quantification. The mobile phase consisted of Milli-Q water with 0.1% trifluoroacetic acid (TFA) in pump A and acetonitrile with 0.1% TFA in pump B, with a flow rate ranging from 0.8 to 1.2 mL/min. A 3<sup>2</sup> factorial design was employed to evaluate the robustness of the proposed method, using mobile phase composition (X<sub>1</sub>), flow rate (X<sub>2</sub>), and column temperature (X<sub>3</sub>) as independent variables and peak area (R<sub>1</sub>), retention time (R<sub>2</sub>), and percent recovery (R<sub>3</sub>) as response variables. The calibration range curve (10-500 µg/mL) was best fitted by quadratic regression. The linearity was reported in the above-mentioned range. The accuracy was 99.952% ± 0.961% at the 75% level, 99.58% ± 1.483% at the 100% level, and 99.789% ± 1.936% at the 125% level. The coefficient of variation was below 2% for both intraday and interday measurements, and the limits of detection and quantification were 0.038 and 0.115 µg/mL, respectively. The NASEP solution was stable (99.04% ± 0.0251%) for 48 h at 8°C. The forced degradation study also revealed that the NASEP solution remained stable in an acidic environment for 48 h at 40°C but degraded at 80°C (<i>p</i> < 0.046) in a time-dependent manner. In contrast, it was unstable in an alkaline medium, independent of temperature, and degraded in the presence of strong oxidizing agents (<i>p</i> < 0.039). Furthermore, NASEP encapsulated in a Gly-Arg-Gly-Asp-Ser pentapeptide and low-molecular-weight heparin functionalized metal-organic framework exhibited sustained drug release at acidic pH 5.4. The proposed NASEP quantification method was validated and is suitable for routine analysis in pharmaceutical formulations.</i>

Authors

Institutions

Publication Details

Journal
Assay and Drug Development Technologies
Published
2025-09-18
DOI
https://doi.org/10.1177/1540658x251377978
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of an Reverse Phase High Performance Liquid Chromatography Method for In Vitro Quantification and Degradation Analysis of Naphthol AS-E Phosphate in Bulk Drugs and Nanoparticles

Kangkan Sarma, Mariusz Jaremko, Maha Alsunbul, Abdul-Hamid Emwas et al.
Assay and Drug Development Technologies
Analytical Methods in Pharmaceuticals
article

Validation of an Reverse Phase High Performance Liquid Chromatography Method for In Vitro Quantification and Degradation Analysis of Naphthol AS-E Phosphate in Bulk Drugs and Nanoparticles

Kangkan Sarma, Mariusz Jaremko, Maha Alsunbul, Abdul-Hamid Emwas, Md Habban Akther
article en

Abstract

<i>This study presents the first validated High-performance liquid chromatography (HPLC) technique for quantifying naphthol AS-E phosphate (NASEP) in bulk drugs and nanoparticle formulation. A C18 HPLC cartridge (250 × 4.6 mm, 5 µm particle size) served as the stationary phase for quantification. The mobile phase consisted of Milli-Q water with 0.1% trifluoroacetic acid (TFA) in pump A and acetonitrile with 0.1% TFA in pump B, with a flow rate ranging from 0.8 to 1.2 mL/min. A 3<sup>2</sup> factorial design was employed to evaluate the robustness of the proposed method, using mobile phase composition (X<sub>1</sub>), flow rate (X<sub>2</sub>), and column temperature (X<sub>3</sub>) as independent variables and peak area (R<sub>1</sub>), retention time (R<sub>2</sub>), and percent recovery (R<sub>3</sub>) as response variables. The calibration range curve (10-500 µg/mL) was best fitted by quadratic regression. The linearity was reported in the above-mentioned range. The accuracy was 99.952% ± 0.961% at the 75% level, 99.58% ± 1.483% at the 100% level, and 99.789% ± 1.936% at the 125% level. The coefficient of variation was below 2% for both intraday and interday measurements, and the limits of detection and quantification were 0.038 and 0.115 µg/mL, respectively. The NASEP solution was stable (99.04% ± 0.0251%) for 48 h at 8°C. The forced degradation study also revealed that the NASEP solution remained stable in an acidic environment for 48 h at 40°C but degraded at 80°C (<i>p</i> < 0.046) in a time-dependent manner. In contrast, it was unstable in an alkaline medium, independent of temperature, and degraded in the presence of strong oxidizing agents (<i>p</i> < 0.039). Furthermore, NASEP encapsulated in a Gly-Arg-Gly-Asp-Ser pentapeptide and low-molecular-weight heparin functionalized metal-organic framework exhibited sustained drug release at acidic pH 5.4. The proposed NASEP quantification method was validated and is suitable for routine analysis in pharmaceutical formulations.</i>

Assay and Drug Development TechnologiesVol. 24(2)
Princess Nourah bint Abdulrahman University (SA), King Abdullah University of Science and Technology (SA), Dehradun Institute of Technology University (IN)
Openalex Percentile: Top 71%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.