Experimental results on enhanced water vapor measurement in vacuum chamber by Twin-TQCM utilizing an electric cooler instead of using liquid nitrogen

Japan Aerospace Exploration Agency, JAXA, and Nihon Dempa Kogyo Co., Ltd., NDK, developed an advanced Twin-QCM aiming for flight and exploration, which can be used under cryogenic temperature, i.e., lower than -80 degrees C called as “cryo-use Twin-TQCM (Engineering Model).” In the present study, the performance test results of the cryo-use Twin-TQCM in terms of measuring water vapor under vacuum is presented. As a result, stable deposition can be observed. Based on the results, the mass deposition rates were found to approximate in linear line, i.e., 127 ng/s at 30Pa and 120 ng/s at 3 Pa, respectively. From the measured data, the partial pressure of water can be calculated. When vacuum chamber was kept at 30 Pa of the total vacuum pressure, the partial pressure of water was 1.30 x 10<sup>-2</sup> Pa; at 3 Pa of the total vacuum pressure, the partial pressure of water was 1.23 x 10<sup>-2</sup> Pa, respectively. It just took 30 seconds to determine the partial pressure of water. It can be concluded that such measurement was achieved by the precise performance of the cryo-use Twin-TQCM.

Authors

Institutions

Publication Details

Published
2025-09-18
DOI
https://doi.org/10.1117/12.3063715
Primary Topic
Heat Transfer and Boiling Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental results on enhanced water vapor measurement in vacuum chamber by Twin-TQCM utilizing an electric cooler instead of using liquid nitrogen

Wataru Yoshida, Hiroyuki Kukita, Yuta Tsuchiya, Eiji Miyazaki et al.
Heat Transfer and Boiling Studies
article

Experimental results on enhanced water vapor measurement in vacuum chamber by Twin-TQCM utilizing an electric cooler instead of using liquid nitrogen

Wataru Yoshida, Hiroyuki Kukita, Yuta Tsuchiya, Eiji Miyazaki, T. Yorita, Hiroki Kimura, Tsuyoshi Shiobara, Koichi Fujihira, Chisako Kanzaki, Riyo Yamanaka
article en

Abstract

Japan Aerospace Exploration Agency, JAXA, and Nihon Dempa Kogyo Co., Ltd., NDK, developed an advanced Twin-QCM aiming for flight and exploration, which can be used under cryogenic temperature, i.e., lower than -80 degrees C called as “cryo-use Twin-TQCM (Engineering Model).” In the present study, the performance test results of the cryo-use Twin-TQCM in terms of measuring water vapor under vacuum is presented. As a result, stable deposition can be observed. Based on the results, the mass deposition rates were found to approximate in linear line, i.e., 127 ng/s at 30Pa and 120 ng/s at 3 Pa, respectively. From the measured data, the partial pressure of water can be calculated. When vacuum chamber was kept at 30 Pa of the total vacuum pressure, the partial pressure of water was 1.30 x 10<sup>-2</sup> Pa; at 3 Pa of the total vacuum pressure, the partial pressure of water was 1.23 x 10<sup>-2</sup> Pa, respectively. It just took 30 seconds to determine the partial pressure of water. It can be concluded that such measurement was achieved by the precise performance of the cryo-use Twin-TQCM.

Japan Aerospace Exploration Agency (JP), Nihon Dempa Kogyo (Japan) (JP)
Openalex Percentile: Top 74%
Heat Transfer and Boiling Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Experimental results on enhanced water vapor measurement in vacuum chamber by Twin-TQCM utilizing an electric cooler instead of using liquid nitrogen — Wataru Yoshida, Hiroyuki Kukita, et al. · (2025) | TGRS Research Map | TGRS