Simultaneous Screening of Multiple Persistent Organic Pollutant Contamination via Excitation–Emission Matrix and Image Recognition Artificial Intelligence

The aim of this study was to devise a methodology for the on-site evaluation of the potential presence of persistent organic pollutants (POPs) in incoming waste materials. A novel approach to POP screening was developed, integrating an excitation–emission matrix method, which facilitates facile and comprehensive measurement, with machine learning of the resulting spectral images. With this approach, it is possible to determine the presence or absence of POPs with very high accuracy for screening, with a correct response rate of ≥75% and a specificity ≥80%. Assuming that this method is applied to actual delivery, we estimate that it is possible to obtain a discrimination result in about 10 min after sample removal.

Authors

Institutions

Publication Details

Journal
Pollutants
Published
2025-09-18
DOI
https://doi.org/10.3390/pollutants5030031
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simultaneous Screening of Multiple Persistent Organic Pollutant Contamination via Excitation–Emission Matrix and Image Recognition Artificial Intelligence

S. Nakai, Shogo Sakita, Wataru Nishijima, Mayuko Yagishita et al.
Pollutants
Advanced Chemical Sensor Technologies
article

Simultaneous Screening of Multiple Persistent Organic Pollutant Contamination via Excitation–Emission Matrix and Image Recognition Artificial Intelligence

S. Nakai, Shogo Sakita, Wataru Nishijima, Mayuko Yagishita, Kazuyuki Nishimura
article en

Abstract

The aim of this study was to devise a methodology for the on-site evaluation of the potential presence of persistent organic pollutants (POPs) in incoming waste materials. A novel approach to POP screening was developed, integrating an excitation–emission matrix method, which facilitates facile and comprehensive measurement, with machine learning of the resulting spectral images. With this approach, it is possible to determine the presence or absence of POPs with very high accuracy for screening, with a correct response rate of ≥75% and a specificity ≥80%. Assuming that this method is applied to actual delivery, we estimate that it is possible to obtain a discrimination result in about 10 min after sample removal.

PollutantsVol. 5(3)
Hiroshima University (JP), Prefectural University of Hiroshima (JP), Hiroshima Institute of Technology (JP), Higashihiroshima Medical Center (JP)
Openalex Percentile: Top 76%
Advanced Chemical Sensor Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.