X-RAY DIFFRACTION TOMOGRAPHY: IMAGE FILTERING BY SINGULAR VALUE DECOMPOSITION AND 1D SMOOTHING WHITTAKER-EILERS METHODS

Digital processing of the 2D noisy X-ray diffraction images (2D-XDI) of a single point defect in Si(111) crystal, registered at the level of dispersion of statistical Gaussian noise of the detector using filtering methods such as singular value decomposition and 1D-line-by-line smoothing of test 2D-XDIs, is carried out. The efficiency of digital filtering of 2D-XDI is evaluated and analyzed by means of control parameter FOM (figure-of-merit) value of reconstruction of the displacement field function of a point defect of Coulomb type f(r-r), (h - diffraction vector, r - radius-vector of the defect position in the sample). It is shown that the filtering technique using the singular value decomposition of 2D-XDI works significantly better than the 1D linear-by-line smoothing method of 2D-XDI, which, apparently, in relation to our problem requires further research on its improvement.

Authors

Publication Details

Journal
Кристаллография / Crystallography Reports
Published
2025-01-01
DOI
https://doi.org/10.7868/s3034551025040016
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

X-RAY DIFFRACTION TOMOGRAPHY: IMAGE FILTERING BY SINGULAR VALUE DECOMPOSITION AND 1D SMOOTHING WHITTAKER-EILERS METHODS

F. N. Chukhovskiǐ
Кристаллография / Crystallography Reports
Medical Imaging Techniques and Applications
article

X-RAY DIFFRACTION TOMOGRAPHY: IMAGE FILTERING BY SINGULAR VALUE DECOMPOSITION AND 1D SMOOTHING WHITTAKER-EILERS METHODS

F. N. Chukhovskiǐ
article en

Abstract

Digital processing of the 2D noisy X-ray diffraction images (2D-XDI) of a single point defect in Si(111) crystal, registered at the level of dispersion of statistical Gaussian noise of the detector using filtering methods such as singular value decomposition and 1D-line-by-line smoothing of test 2D-XDIs, is carried out. The efficiency of digital filtering of 2D-XDI is evaluated and analyzed by means of control parameter FOM (figure-of-merit) value of reconstruction of the displacement field function of a point defect of Coulomb type f(r-r), (h - diffraction vector, r - radius-vector of the defect position in the sample). It is shown that the filtering technique using the singular value decomposition of 2D-XDI works significantly better than the 1D linear-by-line smoothing method of 2D-XDI, which, apparently, in relation to our problem requires further research on its improvement.

Кристаллография / Crystallography ReportsVol. 70(4)
Openalex Percentile: Top 62%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.