Impact of Region of Interest Size on Semi-Quantification of Myocardial <sup>99m</sup>Tc-pyrophosphate Uptake in Suspected Transthyretin Cardiac Amyloidosis

<i>Background</i>: This study aimed to evaluate the optimal region of interest (ROI) size of the heart-to-contralateral (H/CL) ratio on planar imaging for detecting myocardial technetium-99m pyrophosphate (PYP) uptake in patients with suspected transthyretin cardiac amyloidosis (ATTR-CA) and to assess the impact of ROI size on intra- and interobserver variability in the H/CL ratio. <i>Methods</i>: We retrospectively analyzed 90 consecutive patients who underwent PYP imaging for ATTR-CA evaluation after excluding 20 patients without myocardial PYP uptake on planar images (i.e., Grade 0). The H/CL ratio was measured using three ROI sizes (4.5 cm, 3 cm, and 2 cm). Receiver operating characteristic (ROC) analysis was used to evaluate the performance of each ROI size in detecting positive PYP single-photon emission computed tomography (SPECT). Intra- and inter-observer variability was assessed using intraclass correlation coefficients (ICCs). <i>Results</i>: Grade 2-3 myocardial PYP uptake on SPECT was observed in 41 (46%) patients. ROC analysis revealed no significant differences in the area under the curve among the various ROI sizes at 1 hour (0.68, 0.71, and 0.71 for the 4.5-, 3-, and 2-cm ROIs, respectively; <i>P</i>=0.44) or 3 hours (0.71, 0.72, and 0.72 for the 4.5-, 3-, and 2-cm ROIs, respectively; <i>P</i>=0.86). The largest ROI (4.5 cm) demonstrated the highest reproducibility, with excellent intra-observer (ICC=0.949) and inter-observer (ICC=0.906) agreement. <i>Conclusions</i>: The size of the ROI used to calculate the H/CL ratio did not significantly affect the detection of myocardial PYP uptake in patients with suspected ATTR-CA. Using a larger ROI size that covers the entire heart may improve the reproducibility of the H/CL ratio measurement.

Authors

Institutions

Publication Details

Journal
Annals of Nuclear Cardiology
Published
2025-01-01
DOI
https://doi.org/10.17996/anc.25-00005
Citations
1
Primary Topic
Amyloidosis: Diagnosis, Treatment, Outcomes
Type
article
Field-Weighted Citation Impact
0.81
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Region of Interest Size on Semi-Quantification of Myocardial 99mTc-pyrophosphate Uptake in Suspected Transthyretin Cardiac Amyloidosis

Tamaki Kudo, Atsushi Nagase, Tadao Aikawa, Noriko Oyama‐Manabe et al.
1 citations
Annals of Nuclear Cardiology
Amyloidosis: Diagnosis, Treatment, Outcomes
0.81
article

Impact of Region of Interest Size on Semi-Quantification of Myocardial 99mTc-pyrophosphate Uptake in Suspected Transthyretin Cardiac Amyloidosis

Tamaki Kudo, Atsushi Nagase, Tadao Aikawa, Noriko Oyama‐Manabe, Hiroaki Toyama, Osamu Manabe, Toshinori Saitou
article en
1 citations

Abstract

<i>Background</i>: This study aimed to evaluate the optimal region of interest (ROI) size of the heart-to-contralateral (H/CL) ratio on planar imaging for detecting myocardial technetium-99m pyrophosphate (PYP) uptake in patients with suspected transthyretin cardiac amyloidosis (ATTR-CA) and to assess the impact of ROI size on intra- and interobserver variability in the H/CL ratio. <i>Methods</i>: We retrospectively analyzed 90 consecutive patients who underwent PYP imaging for ATTR-CA evaluation after excluding 20 patients without myocardial PYP uptake on planar images (i.e., Grade 0). The H/CL ratio was measured using three ROI sizes (4.5 cm, 3 cm, and 2 cm). Receiver operating characteristic (ROC) analysis was used to evaluate the performance of each ROI size in detecting positive PYP single-photon emission computed tomography (SPECT). Intra- and inter-observer variability was assessed using intraclass correlation coefficients (ICCs). <i>Results</i>: Grade 2-3 myocardial PYP uptake on SPECT was observed in 41 (46%) patients. ROC analysis revealed no significant differences in the area under the curve among the various ROI sizes at 1 hour (0.68, 0.71, and 0.71 for the 4.5-, 3-, and 2-cm ROIs, respectively; <i>P</i>=0.44) or 3 hours (0.71, 0.72, and 0.72 for the 4.5-, 3-, and 2-cm ROIs, respectively; <i>P</i>=0.86). The largest ROI (4.5 cm) demonstrated the highest reproducibility, with excellent intra-observer (ICC=0.949) and inter-observer (ICC=0.906) agreement. <i>Conclusions</i>: The size of the ROI used to calculate the H/CL ratio did not significantly affect the detection of myocardial PYP uptake in patients with suspected ATTR-CA. Using a larger ROI size that covers the entire heart may improve the reproducibility of the H/CL ratio measurement.

Annals of Nuclear CardiologyVol. 11(1)
Jichi Medical University (JP), Juntendo University (JP), Cardiovascular Center Hokkaido Ohno Hospital (JP), Jichi Medical University Saitama Medical Center (JP)
Openalex Percentile: Top 23%
Amyloidosis: Diagnosis, Treatment, Outcomes
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.