Assessing the feasibility of deep learning-based attenuation correction using photon emission data in <sup>18</sup>F-FDG images for dedicated head and neck PET scanners

This study aimed to evaluate the use of deep learning techniques to produce measured attenuation-corrected (MAC) images from non-attenuation-corrected (NAC) F-FDG PET images, focusing on head and neck imaging. A Residual Network (ResNet) was used to train 2D head and neck PET images from 114 patients (12,068 slices) without pathology or artifacts. For validation during training and testing, 21 and 24 patient images without pathology and artifacts were used, and 12 images with pathologies were used for independent testing. Prediction accuracy was assessed using metrics such as RMSE, SSIM, PSNR, and MSE. The impact of unseen pathologies on the network was evaluated by measuring contrast and SNR in tumoral/hot regions of both reference and predicted images. Statistical significance between the contrast and SNR of reference and predicted images was assessed using a paired-sample t-test. Two nuclear medicine physicians evaluated the predicted head and neck MAC images, finding them visually similar to reference images. In the normal test group, PSNR, SSIM, RMSE, and MSE were 44.02 ± 1.77, 0.99 ± 0.002, 0.007 ± 0.0019, and 0.000053 ± 0.000030, respectively. For the pathological test group, values were 43.14 ± 2.10, 0.99 ± 0.005, 0.0078 ± 0.0015, and 0.000063 ± 0.000026, respectively. No significant differences were found in SNR and contrast between reference and test images without pathology (p-value > 0.05), but significant differences were found in pathological images (p-value < 0.05). The deep learning network demonstrated the ability to directly generate head and neck MAC images that closely resembled the reference images. With additional training data, the model has the potential to be utilized in dedicated head and neck PET scanners without the requirement of computed tomography [CT] for attenuation correction.

Authors

Institutions

Publication Details

Journal
Biomedical Physics & Engineering Express
Published
2025-09-18
DOI
https://doi.org/10.1088/2057-1976/ae08ba
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing the feasibility of deep learning-based attenuation correction using photon emission data in 18F-FDG images for dedicated head and neck PET scanners

Saeed Farzenefar, Amin Amiri Tehrani Zade, Peyman Sheikhzadeh, Mohammadreza Ay et al.
Biomedical Physics & Engineering Express
Radiomics and Machine Learning in Medical Imaging
article

Assessing the feasibility of deep learning-based attenuation correction using photon emission data in 18F-FDG images for dedicated head and neck PET scanners

Saeed Farzenefar, Amin Amiri Tehrani Zade, Peyman Sheikhzadeh, Mohammadreza Ay, Ali Ghafari, Mahsa Shahrbabaki Mofrad, Farahnaz Aghahosseini
article en

Abstract

This study aimed to evaluate the use of deep learning techniques to produce measured attenuation-corrected (MAC) images from non-attenuation-corrected (NAC) F-FDG PET images, focusing on head and neck imaging. A Residual Network (ResNet) was used to train 2D head and neck PET images from 114 patients (12,068 slices) without pathology or artifacts. For validation during training and testing, 21 and 24 patient images without pathology and artifacts were used, and 12 images with pathologies were used for independent testing. Prediction accuracy was assessed using metrics such as RMSE, SSIM, PSNR, and MSE. The impact of unseen pathologies on the network was evaluated by measuring contrast and SNR in tumoral/hot regions of both reference and predicted images. Statistical significance between the contrast and SNR of reference and predicted images was assessed using a paired-sample t-test. Two nuclear medicine physicians evaluated the predicted head and neck MAC images, finding them visually similar to reference images. In the normal test group, PSNR, SSIM, RMSE, and MSE were 44.02 ± 1.77, 0.99 ± 0.002, 0.007 ± 0.0019, and 0.000053 ± 0.000030, respectively. For the pathological test group, values were 43.14 ± 2.10, 0.99 ± 0.005, 0.0078 ± 0.0015, and 0.000063 ± 0.000026, respectively. No significant differences were found in SNR and contrast between reference and test images without pathology (p-value > 0.05), but significant differences were found in pathological images (p-value < 0.05). The deep learning network demonstrated the ability to directly generate head and neck MAC images that closely resembled the reference images. With additional training data, the model has the potential to be utilized in dedicated head and neck PET scanners without the requirement of computed tomography [CT] for attenuation correction.

Biomedical Physics & Engineering ExpressVol. 11(5)
Iran University of Medical Sciences (IR), Tabriz University of Medical Sciences (IR), Mashhad University of Medical Sciences (IR), Islamic Azad University Medical Branch of Tehran (IR), Tehran University of Medical Sciences (IR)
Openalex Percentile: Top 62%
Radiomics and Machine Learning in Medical Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.