From zero- to few-shot: deep temporal learning of wrist EMG enables scalable cross-user gesture recognition
<i>Objective.</i>Wrist electromyography (EMG) is emerging as an enticing wearable input modality for human-machine interaction. Traditionally recorded from the forearm for use in transradial prostheses, wrist-based EMG sensors are now being integrated into devices such as watches and wristbands for hand gesture recognition (HGR). Consumer familiarity with wrist-worn devices makes wrist EMG a compelling option, but the need for individualized user calibration remains a challenge.<i>Approach.</i>This study therefore evaluated various cross-user models to reduce the calibration burden and compared wrist- and forearm-based models. Eight different machine learning architectures were evaluated across 33 users, using varying amounts of data from the end user.<i>Main results.</i>A temporal convolutional network-bidirectional long short-term memory architecture, applied for the first time to EMG classification, was found to significantly (<i>p</i> < 0.05) outperform other tested machine learning architectures. An inter-day feature set combined with<i>Z</i>-score normalization achieved the best performance when classifying five gestures (plus a rest class) using either wrist or forearm EMG. Consistent with other recent results, wrist EMG consistently outperformed forearm EMG in all analyses, including within- and across-user comparisons (<i>p</i> < 0.05). In cross-user models, wrist EMG demonstrated a zero-shot performance of 78.2%, compared to 71.6% for forearm EMG (<i>p</i> < 0.05). Introducing one calibration repetition from the end user increased one-shot performance of wrist EMG to 91.6%, compared to 86.9% for forearm EMG (<i>p</i> < 0.05). Adding further training repetitions boosted wrist EMG performance to 98.3%, compared to 97.4% for forearm EMG.<i>Significance.</i>These findings provide new evidence supporting the viability of wrist EMG for cross-user HGR models that generalize to new users with minimal calibration, suggesting promising potential for its broader adoption in wearable devices.
Authors
- Angkoon Phinyomark (ORCID: https://orcid.org/0000-0003-0170-3245)
- Erik Scheme (ORCID: https://orcid.org/0000-0002-4421-1016)
- Fady S. Botros (ORCID: https://orcid.org/0000-0002-9311-1345)
- Heather E. Williams (ORCID: https://orcid.org/0000-0001-8051-3751)
Institutions
- University of New Brunswick (CA)
- MathWorks (United States) (US)
Publication Details
- Journal
- Journal of Neural Engineering
- Published
- 2025-09-18
- DOI
- https://doi.org/10.1088/1741-2552/ae08eb
- Citations
- 1
- Primary Topic
- Muscle activation and electromyography studies
- Type
- article
- Field-Weighted Citation Impact
- 0.67