Resting blood pressure estimation from a low-resolution single thermal facial image

Abstract In recent years, the prevalence of hypertension has increased, making routine blood pressure monitoring crucial for early detection and prevention. Our research group focused on facial skin temperature, a cardiovascular indicator that can be remotely measured using infrared thermography. It has been studied for non-contact blood pressure estimation based on the spatial characteristics of captured thermal facial images (TFIs). Previous studies have estimated the resting blood pressure based on spatial features extracted by applying independent component analysis (ICA) to acquired TFIs. In practical applications, the use of low-resolution TFIs is considered cost-effective and advantageous for reducing the burden of data management owing to the smaller data volume. However, the reduced resolution could potentially result in the loss of critical information necessary for accurate blood pressure estimation. Therefore, it is essential to evaluate whether low-resolution TFIs can maintain sufficient estimation accuracy for practical implementation. In this study, we developed a resting blood pressure estimation model using low-resolution TFIs with a resolution of 160 $$\times$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mo>×</mml:mo> </mml:math> 120 pixels. We compared its estimation accuracy with that of a conventional model employing higher-resolution TFIs (320 $$\times$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mo>×</mml:mo> </mml:math> 256 pixels). Following the procedure used in the previous studies, ICA was applied to the TFIs, and a linear support vector regression (SVR) model was constructed using the weights of the selected independent components as input features achieving a root-mean-square error (RMSE) of 13.1 mmHg and a correlation coefficient ( r ) of 0.369.

Authors

Institutions

Publication Details

Journal
Artificial Life and Robotics
Published
2025-09-19
DOI
https://doi.org/10.1007/s10015-025-01062-w
Primary Topic
Infrared Thermography in Medicine
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Resting blood pressure estimation from a low-resolution single thermal facial image

Kent Nagumo, Akio Nozawa, Hana Furudate
Artificial Life and Robotics
Infrared Thermography in Medicine
article

Resting blood pressure estimation from a low-resolution single thermal facial image

Kent Nagumo, Akio Nozawa, Hana Furudate
article en

Abstract

Abstract In recent years, the prevalence of hypertension has increased, making routine blood pressure monitoring crucial for early detection and prevention. Our research group focused on facial skin temperature, a cardiovascular indicator that can be remotely measured using infrared thermography. It has been studied for non-contact blood pressure estimation based on the spatial characteristics of captured thermal facial images (TFIs). Previous studies have estimated the resting blood pressure based on spatial features extracted by applying independent component analysis (ICA) to acquired TFIs. In practical applications, the use of low-resolution TFIs is considered cost-effective and advantageous for reducing the burden of data management owing to the smaller data volume. However, the reduced resolution could potentially result in the loss of critical information necessary for accurate blood pressure estimation. Therefore, it is essential to evaluate whether low-resolution TFIs can maintain sufficient estimation accuracy for practical implementation. In this study, we developed a resting blood pressure estimation model using low-resolution TFIs with a resolution of 160 $$\times$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mo>×</mml:mo> </mml:math> 120 pixels. We compared its estimation accuracy with that of a conventional model employing higher-resolution TFIs (320 $$\times$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mo>×</mml:mo> </mml:math> 256 pixels). Following the procedure used in the previous studies, ICA was applied to the TFIs, and a linear support vector regression (SVR) model was constructed using the weights of the selected independent components as input features achieving a root-mean-square error (RMSE) of 13.1 mmHg and a correlation coefficient ( r ) of 0.369.

Artificial Life and RoboticsVol. 30(4)
Aoyama Gakuin University (JP)
Openalex Percentile: Top 62%
Infrared Thermography in Medicine
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.