Software-Aided Versus Unassisted Fluoroscopy in Optimising Limb Length and Component Placement in Direct Anterior Total Hip Arthroplasty

Background Intraoperative fluoroscopy has been the gold standard in direct anterior approach (DAA) total hip arthroplasty (THA) to assess the position of the components. Fluoroscopy could be aided by software to help surgeons plan and execute the THA optimally; however its clinical effectiveness has not been proven. This study assessed the use of fluoroscopy with intraoperative software to evaluate the ability of the software to accurately measure the component position and leg length discrepancy (LLD) in DAA. Methods Thirty-eight patients (39 procedures) were prospectively selected from consecutive patients treated using software-aided fluoroscopy (Group 1). Thirty-eight patients (38 procedures) were retrospectively enrolled into the control group (Group 2) from patients using intraoperative fluoroscopy without software analysis. Patients in both groups underwent THA using DAA. A mobile C-arm image intensifier unit was used to obtain images of the affected hip intraoperatively. In Group 1, the LLD and cup inclination were calculated intraoperatively by the software. The LLD, cup inclination and anteversion were measured for both groups using antero-posterior (AP) X-rays at six weeks postoperatively and were compared to the preoperatively planned targets. Results The mean postoperative LLD was significantly less in Group 1 when compared to Group 2 (2.2mm vs 4.6mm, p<0.01). In Group 1, 100% of hips (39/39) had a radiographic LLD within 10mm compared with 97% (37/38) in Group 2. The cup inclination and cup anteversion achieved within Group 1 were closer to the planned inclination and anteversion when compared to the control. Conclusions Intraoperative software analysis of fluoroscopy in THA aids accurate implantation of THA using the DAA approach with regard to leg length equality and acetabular component positioning.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-09-18
DOI
https://doi.org/10.7759/cureus.92660
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Software-Aided Versus Unassisted Fluoroscopy in Optimising Limb Length and Component Placement in Direct Anterior Total Hip Arthroplasty

Leina Suzuki, Shuhei Hiyama, Yash Wagh, Francis Connon et al.
Cureus
Orthopaedic implants and arthroplasty
article

Software-Aided Versus Unassisted Fluoroscopy in Optimising Limb Length and Component Placement in Direct Anterior Total Hip Arthroplasty

Leina Suzuki, Shuhei Hiyama, Yash Wagh, Francis Connon, Daevyd Rodda, Hemant Pandit, Selin Munir
article en

Abstract

Background Intraoperative fluoroscopy has been the gold standard in direct anterior approach (DAA) total hip arthroplasty (THA) to assess the position of the components. Fluoroscopy could be aided by software to help surgeons plan and execute the THA optimally; however its clinical effectiveness has not been proven. This study assessed the use of fluoroscopy with intraoperative software to evaluate the ability of the software to accurately measure the component position and leg length discrepancy (LLD) in DAA. Methods Thirty-eight patients (39 procedures) were prospectively selected from consecutive patients treated using software-aided fluoroscopy (Group 1). Thirty-eight patients (38 procedures) were retrospectively enrolled into the control group (Group 2) from patients using intraoperative fluoroscopy without software analysis. Patients in both groups underwent THA using DAA. A mobile C-arm image intensifier unit was used to obtain images of the affected hip intraoperatively. In Group 1, the LLD and cup inclination were calculated intraoperatively by the software. The LLD, cup inclination and anteversion were measured for both groups using antero-posterior (AP) X-rays at six weeks postoperatively and were compared to the preoperatively planned targets. Results The mean postoperative LLD was significantly less in Group 1 when compared to Group 2 (2.2mm vs 4.6mm, p<0.01). In Group 1, 100% of hips (39/39) had a radiographic LLD within 10mm compared with 97% (37/38) in Group 2. The cup inclination and cup anteversion achieved within Group 1 were closer to the planned inclination and anteversion when compared to the control. Conclusions Intraoperative software analysis of fluoroscopy in THA aids accurate implantation of THA using the DAA approach with regard to leg length equality and acetabular component positioning.

CureusVol. 17(9)
Jichi Medical University (JP), NIHR Oxford Musculoskeletal Biomedical Research Centre (GB), Sunshine Coast University Hospital (AU), NIHR Leeds Musculoskeletal Biomedical Research Unit (GB), Engeneic (Australia) (AU), Jichi Medical University Hospital (JP)
Openalex Percentile: Top 59%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.