Multiframe blind deconvolution method using an in-plane rotating sample

Mirror-based X-ray microscopes have the problem that wavefront aberrations caused by mirror fabrication and alignment errors degrade the spatial resolution. To overcome the problem, we proposed a new blind deconvolution method using an in-plane rotating sample that can identify and remove the blur to improve the resolution. Demonstration experiments were carried out at SPring-8 BL29XUL using an X-ray microscope equipped with an advanced Kirkpatrick-Baez mirror. The intensity image obtained with an X-ray camera was blurred due to contamination of the used mirrors. After deconvolution, a clear image was obtained. The blur caused by the mirrors was perfectly identified and removed. The resolution of the reconstructed image was estimated to be 34 nm, which is close to the expected diffraction limit.

Authors

Institutions

Publication Details

Published
2025-09-18
DOI
https://doi.org/10.1117/12.3063747
Primary Topic
Spectroscopy and Chemometric Analyses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multiframe blind deconvolution method using an in-plane rotating sample

Toshiki Ito, So Ito, Yuki IWAMI, Yoshiki Kohmura et al.
Spectroscopy and Chemometric Analyses
article

Multiframe blind deconvolution method using an in-plane rotating sample

Toshiki Ito, So Ito, Yuki IWAMI, Yoshiki Kohmura, Satoshi Matsuyama, Makina Yabashi, Takato Inoue, Shinnosuke Kurimoto
article en

Abstract

Mirror-based X-ray microscopes have the problem that wavefront aberrations caused by mirror fabrication and alignment errors degrade the spatial resolution. To overcome the problem, we proposed a new blind deconvolution method using an in-plane rotating sample that can identify and remove the blur to improve the resolution. Demonstration experiments were carried out at SPring-8 BL29XUL using an X-ray microscope equipped with an advanced Kirkpatrick-Baez mirror. The intensity image obtained with an X-ray camera was blurred due to contamination of the used mirrors. After deconvolution, a clear image was obtained. The blur caused by the mirrors was perfectly identified and removed. The resolution of the reconstructed image was estimated to be 34 nm, which is close to the expected diffraction limit.

SPring-8 (JP), Nagoya University (JP), The University of Osaka (JP)
Openalex Percentile: Top 72%
Spectroscopy and Chemometric Analyses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.