Establishment and validation of a dose–response curve for semi-automated analysis of dicentric chromosomes induced by 60Co γ-rays

The dicentric chromosome assay serves as the "gold standard" for biodosimetry, playing a crucial role in rapid clinical decision-making during extensive nuclear radiation incidents. This study aimed to develop a semi-automated dose-response curve for the analysis of dicentric chromosomes induced by irradiation of human peripheral blood lymphocytes with 60Co gamma rays. Blood samples were collected from three healthy donors and subjected to irradiation, culture, and harvesting, following International Atomic Energy Agency standard protocols. The Metafer4 system, an automatic scoring system, was utilized to acquire images of the metaphase chromosome segregation phase, and the dose-response curve was constructed through automatic analysis of dicentric chromosomes supplemented by manual verification. The curve was subsequently validated through blind scoring. The results demonstrated that the semi-automated scoring method provides quick and precise dose estimations and offers a viable alternative to manual dicentric chromosome assay. This approach holds significant potential for application in the nuclear emergency management of large-scale radiological events.

Authors

Institutions

Publication Details

Journal
Radiation Protection Dosimetry
Published
2025-09-12
DOI
https://doi.org/10.1093/rpd/ncaf101
Primary Topic
Carcinogens and Genotoxicity Assessment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Establishment and validation of a dose–response curve for semi-automated analysis of dicentric chromosomes induced by 60Co γ-rays

Qian-Qian Meng, Zhongxin Zhang, Yufeng Guo, Hongyan Liu et al.
Radiation Protection Dosimetry
Carcinogens and Genotoxicity Assessment
article

Establishment and validation of a dose–response curve for semi-automated analysis of dicentric chromosomes induced by 60Co γ-rays

Qian-Qian Meng, Zhongxin Zhang, Yufeng Guo, Hongyan Liu, Ruifeng Zhang, Yue Ren, Xiaoquan Zhang, Xiaozhen Li
article en

Abstract

The dicentric chromosome assay serves as the "gold standard" for biodosimetry, playing a crucial role in rapid clinical decision-making during extensive nuclear radiation incidents. This study aimed to develop a semi-automated dose-response curve for the analysis of dicentric chromosomes induced by irradiation of human peripheral blood lymphocytes with 60Co gamma rays. Blood samples were collected from three healthy donors and subjected to irradiation, culture, and harvesting, following International Atomic Energy Agency standard protocols. The Metafer4 system, an automatic scoring system, was utilized to acquire images of the metaphase chromosome segregation phase, and the dose-response curve was constructed through automatic analysis of dicentric chromosomes supplemented by manual verification. The curve was subsequently validated through blind scoring. The results demonstrated that the semi-automated scoring method provides quick and precise dose estimations and offers a viable alternative to manual dicentric chromosome assay. This approach holds significant potential for application in the nuclear emergency management of large-scale radiological events.

Radiation Protection DosimetryVol. 201(17)
National Institute for Radiological Protection (CN)
Openalex Percentile: Top 69%
Carcinogens and Genotoxicity Assessment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.