Development of a Rapid Diagnostic Test to Distinguish between Emerging Viruses That Cause Hemorrhagic Fever

Viruses that cause the clinical syndrome referred to as viral hemorrhagic fever (VHF) are responsible for numerous infectious disease outbreaks. High-priority emerging viruses include orthoebolaviruses, orthomarburgviruses, Lassa virus, Crimean-Congo hemorrhagic fever virus, Rift Valley fever virus (RVFV), dengue virus (DENV), and yellow fever virus (YFV). Many of these viruses cause a similar clinical presentation in infected humans and have an overlapping geographic distribution with a risk of coemergence. As such, an antigen rapid diagnostic test to distinguish between these viruses would be beneficial in low-resource settings. In this study, we developed single-plex and multiplex antigen detection lateral flow immunoassays (LFIs) to rapidly detect and distinguish between emerging viruses that can cause VHF. We evaluated two antibody-labeling methods, colloidal gold nanoparticles and cellulose nanobeads (CNBs), to determine which approach would increase assay performance and multiplexing capabilities. Assay performance was evaluated by determining their sensitivity, specificity, matrix evaluation, and stability testing. All assays were highly specific, with no crossreactivity observed for the single-plex assays. Several of the assays performed better with the CNBs, including the DENV, YFV, RVFV, and orthomarburgvirus LFIs. No matrix effect was observed with most of the assays except that serum did impact the RVFV and DENV assays. In general, the multiplex assays were less sensitive compared with their respective single-plex assay. The most successful assays were the single-plex CNB LFIs assembled into an eight-plex cartridge, which allows for rapid and simultaneous testing of antigen to seven viruses.

Authors

Institutions

Publication Details

Journal
American Journal of Tropical Medicine and Hygiene
Published
2025-09-18
DOI
https://doi.org/10.4269/ajtmh.25-0168
Primary Topic
Viral Infections and Vectors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a Rapid Diagnostic Test to Distinguish between Emerging Viruses That Cause Hemorrhagic Fever

Scott P. Olschner, Darci R. Smith, Keersten M. Ricks, Andrew Wilson et al.
American Journal of Tropical Medicine and Hygiene
Viral Infections and Vectors
article

Development of a Rapid Diagnostic Test to Distinguish between Emerging Viruses That Cause Hemorrhagic Fever

Scott P. Olschner, Darci R. Smith, Keersten M. Ricks, Andrew Wilson, Heather Poeck-Goux, Madison Ruschaupt
article en

Abstract

Viruses that cause the clinical syndrome referred to as viral hemorrhagic fever (VHF) are responsible for numerous infectious disease outbreaks. High-priority emerging viruses include orthoebolaviruses, orthomarburgviruses, Lassa virus, Crimean-Congo hemorrhagic fever virus, Rift Valley fever virus (RVFV), dengue virus (DENV), and yellow fever virus (YFV). Many of these viruses cause a similar clinical presentation in infected humans and have an overlapping geographic distribution with a risk of coemergence. As such, an antigen rapid diagnostic test to distinguish between these viruses would be beneficial in low-resource settings. In this study, we developed single-plex and multiplex antigen detection lateral flow immunoassays (LFIs) to rapidly detect and distinguish between emerging viruses that can cause VHF. We evaluated two antibody-labeling methods, colloidal gold nanoparticles and cellulose nanobeads (CNBs), to determine which approach would increase assay performance and multiplexing capabilities. Assay performance was evaluated by determining their sensitivity, specificity, matrix evaluation, and stability testing. All assays were highly specific, with no crossreactivity observed for the single-plex assays. Several of the assays performed better with the CNBs, including the DENV, YFV, RVFV, and orthomarburgvirus LFIs. No matrix effect was observed with most of the assays except that serum did impact the RVFV and DENV assays. In general, the multiplex assays were less sensitive compared with their respective single-plex assay. The most successful assays were the single-plex CNB LFIs assembled into an eight-plex cartridge, which allows for rapid and simultaneous testing of antigen to seven viruses.

American Journal of Tropical Medicine and HygieneVol. 113(5)
Naval Medical Research Command (US), Parsons (United States) (US), United States Army Medical Research Institute of Infectious Diseases (US), United States Army Medical Research and Development Command (US)
Openalex Percentile: Top 70%
Viral Infections and Vectors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.