Analyses and Protection Methods of Single-phase Broken-line Complex Faults for Distribution Line

The occurrence of broken-line fault in distribution lines has been increasing annually, often accompanied by grounding fault, forming a complex fault. It will generate negative and zero sequence components, severely affecting normal operation of loads. Single-phase broken-line fault is typical in all kinds of broken-line faults, so this paper takes it as the research object, analyses and summarizes features of electrical quantities when single-phase broken-line fault with or without a grounding fault occurs, and proposes a set of criteria for single-phase broken-line fault. Additionally, methods for judging fault types and locations based on voltage criteria are studied. The impacts of asymmetry operation, instrument transformer broken-lines, and other abnormal conditions on the proposed criteria are analyzed, along with corresponding protection strategies. Finally, simulation is carried out in PSCAD/EMTDC, which validate the theoretical analysis and the effectiveness of the proposed protection methods.

Authors

Institutions

Publication Details

Published
2025-07-04
DOI
https://doi.org/10.1109/icpet66029.2025.11160359
Citations
1
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
1.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analyses and Protection Methods of Single-phase Broken-line Complex Faults for Distribution Line

Fangyuan Wang, Shuang Liang, Wei Cong, Xiaoyong Yu et al.
1 citations
Power Systems Fault Detection
1.21
article

Analyses and Protection Methods of Single-phase Broken-line Complex Faults for Distribution Line

Fangyuan Wang, Shuang Liang, Wei Cong, Xiaoyong Yu, Kewen Li, Zongwen Shuai
article en
1 citations

Abstract

The occurrence of broken-line fault in distribution lines has been increasing annually, often accompanied by grounding fault, forming a complex fault. It will generate negative and zero sequence components, severely affecting normal operation of loads. Single-phase broken-line fault is typical in all kinds of broken-line faults, so this paper takes it as the research object, analyses and summarizes features of electrical quantities when single-phase broken-line fault with or without a grounding fault occurs, and proposes a set of criteria for single-phase broken-line fault. Additionally, methods for judging fault types and locations based on voltage criteria are studied. The impacts of asymmetry operation, instrument transformer broken-lines, and other abnormal conditions on the proposed criteria are analyzed, along with corresponding protection strategies. Finally, simulation is carried out in PSCAD/EMTDC, which validate the theoretical analysis and the effectiveness of the proposed protection methods.

Electric Power Research Institute (US), Shandong University (CN), Power Grid Corporation (India) (IN)
Openalex Percentile: Top 17%
Power Systems Fault Detection
1.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analyses and Protection Methods of Single-phase Broken-line Complex Faults for Distribution Line — Fangyuan Wang, Shuang Liang, et al. · (2025) | TGRS Research Map | TGRS