Second Harmonic Active Suppression Converter for Battery Pulsating Current

This paper proposes a second harmonic active suppression converter (SHASC) to suppress the second harmonic current (SHC) generated by the two-stage single-phase inverter (TSI). The SHASC converter consists of an intermediate DC bus capacitor and a full-bridge circuit. One side of the full-bridge circuit serves as the input port, through which the intermediate DC bus capacitor is connected to the DC bus of the single-phase grid-connected inverter. The other side acts as the output port, connecting the intermediate DC bus capacitor to the battery energy storage system (BESS). By actively controlling the half-bridge on the input side of this converter, the intermediate DC bus capacitor can absorb the SHC output by the TSI, thus actively suppressing the SHC at the battery terminals. Compared with existing solutions, it reduces the size of passive components and the complexity of control.

Authors

Institutions

Publication Details

Published
2025-07-04
DOI
https://doi.org/10.1109/icpet66029.2025.11160453
Primary Topic
Induction Heating and Inverter Technology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Second Harmonic Active Suppression Converter for Battery Pulsating Current

Changlin Mei, C. M. Wang, Hongxun Qi, Gang Shi et al.
Induction Heating and Inverter Technology
article

Second Harmonic Active Suppression Converter for Battery Pulsating Current

Changlin Mei, C. M. Wang, Hongxun Qi, Gang Shi, Jianwen Zhang, Pin Wu, Linpeng Yao, Weiwen Guo
article en

Abstract

This paper proposes a second harmonic active suppression converter (SHASC) to suppress the second harmonic current (SHC) generated by the two-stage single-phase inverter (TSI). The SHASC converter consists of an intermediate DC bus capacitor and a full-bridge circuit. One side of the full-bridge circuit serves as the input port, through which the intermediate DC bus capacitor is connected to the DC bus of the single-phase grid-connected inverter. The other side acts as the output port, connecting the intermediate DC bus capacitor to the battery energy storage system (BESS). By actively controlling the half-bridge on the input side of this converter, the intermediate DC bus capacitor can absorb the SHC output by the TSI, thus actively suppressing the SHC at the battery terminals. Compared with existing solutions, it reduces the size of passive components and the complexity of control.

Shanghai Jiao Tong University (CN), Energy Storage Systems (United States) (US), China Power Engineering Consulting Group (China) (CN)
Openalex Percentile: Top 74%
Induction Heating and Inverter Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.