Enhancing Surge Protection Scheme in Distribution Networks of Nepal for Lightning Overvoltage Analysis at Goldhunga Feeder (using EMTP-RV)

Lightning-induced overvoltages pose a major threat to Nepal’s Integrated Nepal Power System (INPS), particularly in mountainous regions with high lightning activity. This study analyzes surge behavior and mitigation strategies across 132 kV , 66 kV , and 33 kV transmission lines, as well as 11 kV and 0.4 kV distribution networks, focusing on a case study of the 11 kV Goldhunga feeder in Tarkeshwor Municipality, Kathmandu Valley. The feeder is modeled using field data from the Nepal Electricity Authority (NEA), while higher-voltage lines are represented using typical INPS configurations adapted from IEEE/CIGRÉ standards, incorporating NEA-specific conductor types (e.g., ACSR Dog for 33 kV , ACSR Panther for 66/132 kV), tower footing resistance (10–100 Ω), and insulation levels suited to Nepal’s high lightning ground flash density (up to 25.31 strokes/km²). EMTP-RV simulations with 2020–2023 lightning data evaluate critical factors such as Metal Oxide Surge Arrester (MOSA) placement, arrester lead length, TFR, and secondary-side protection. Results show that locating MOSAs within 3 m of transformer terminals, keeping lead lengths below 1 m, and maintaining TFR under 10 Ω significantly reduces peak overvoltages and surge transfer risks, while secondary-side arresters effectively suppress transferred surges to protect transformers and downstream equipment. Conversely, inadequate protection at lower voltages (11 kV and 0.4 kV) causes severe voltage stress and equipment failures. These findings provide a robust, evidence-based framework for optimizing lightning protection in Nepal’s lightning-prone, topographically challenging grid, enhancing reliability, minimizing outages, and offering valuable insights for other mountainous power systems worldwide.

Authors

Institutions

Publication Details

Journal
Journal of Advanced College of Engineering and Management
Published
2025-09-18
DOI
https://doi.org/10.3126/jacem.v11i1.84547
Primary Topic
Lightning and Electromagnetic Phenomena
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing Surge Protection Scheme in Distribution Networks of Nepal for Lightning Overvoltage Analysis at Goldhunga Feeder (using EMTP-RV)

Khem N. Poudyal, Shriram Sharma, Barun Ghimire, Nava Raj Karki
Journal of Advanced College of Engineering and Management
Lightning and Electromagnetic Phenomena
article

Enhancing Surge Protection Scheme in Distribution Networks of Nepal for Lightning Overvoltage Analysis at Goldhunga Feeder (using EMTP-RV)

Khem N. Poudyal, Shriram Sharma, Barun Ghimire, Nava Raj Karki
article en

Abstract

Lightning-induced overvoltages pose a major threat to Nepal’s Integrated Nepal Power System (INPS), particularly in mountainous regions with high lightning activity. This study analyzes surge behavior and mitigation strategies across 132 kV , 66 kV , and 33 kV transmission lines, as well as 11 kV and 0.4 kV distribution networks, focusing on a case study of the 11 kV Goldhunga feeder in Tarkeshwor Municipality, Kathmandu Valley. The feeder is modeled using field data from the Nepal Electricity Authority (NEA), while higher-voltage lines are represented using typical INPS configurations adapted from IEEE/CIGRÉ standards, incorporating NEA-specific conductor types (e.g., ACSR Dog for 33 kV , ACSR Panther for 66/132 kV), tower footing resistance (10–100 Ω), and insulation levels suited to Nepal’s high lightning ground flash density (up to 25.31 strokes/km²). EMTP-RV simulations with 2020–2023 lightning data evaluate critical factors such as Metal Oxide Surge Arrester (MOSA) placement, arrester lead length, TFR, and secondary-side protection. Results show that locating MOSAs within 3 m of transformer terminals, keeping lead lengths below 1 m, and maintaining TFR under 10 Ω significantly reduces peak overvoltages and surge transfer risks, while secondary-side arresters effectively suppress transferred surges to protect transformers and downstream equipment. Conversely, inadequate protection at lower voltages (11 kV and 0.4 kV) causes severe voltage stress and equipment failures. These findings provide a robust, evidence-based framework for optimizing lightning protection in Nepal’s lightning-prone, topographically challenging grid, enhancing reliability, minimizing outages, and offering valuable insights for other mountainous power systems worldwide.

Journal of Advanced College of Engineering and ManagementVol. 11
Nepal Sanskrit University (NP), Nepal Development Research Institute (NP)
Tribhuvan University
Openalex Percentile: Top 82%
Lightning and Electromagnetic Phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.