Usability evaluation of augmented reality glasses for remote support during extracorporeal membrane oxygenation

Extracorporeal membrane oxygenation (ECMO) procedures may result in emergencies requiring the intervention of a perfusionist. However, their arrival results in waiting times that put patients at risk. Hence, nursing staff should be remotely supported using augmented reality (AR) in troubleshooting to improve patient safety. In this study, we aimed to investigate the usability of AR glasses <i>HMT-1</i> and <i>HoloLens 2</i> for remote support during ECMO and to determine the user acceptance of AR in intensive care. Ten nurses tested both glasses in a user test in randomized order under perfusionist guidance to rectify the three ECMO emergencies: a signal alert, a pump failure and reduced blood flow. An investigator rated their skills using a 3-step scheme, and success rates were calculated from the ratings and compared using the Wilcoxon test (α =.05). AR acceptance was assessed using the System Usability Scale (SUS) and User Experience Questionnaire (UEQ). We recorded 12 and 21 use errors with <i>HMT-1</i> and <i>HoloLens 2,</i> respectively. However, significantly fewer use errors occurred with the <i>HMT-1</i> than with <i>HoloLens 2</i> (Z = -1786, p = .046, n = 80) when troubleshooting the pump failure. Most participants rated <i>HoloLens 2</i> as more suitable. AR acceptance was rated as good with a SUS score of 72 (± 11). UEQ ratings for <i>attractiveness</i>, <i>dependability</i>, <i>stimulation</i>, <i>novelty</i>, and <i>efficiency</i> were excellent or good, while <i>perspicuity</i> was rated below average. The results indicate that both AR glasses are suitable for remote support; however, improvements to increase efficiency and patient safety in intensive care are necessary.

Authors

Institutions

Publication Details

Journal
Computational and Structural Biotechnology Journal
Published
2025-01-01
DOI
https://doi.org/10.1016/j.csbj.2025.09.025
Primary Topic
Augmented Reality Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Usability evaluation of augmented reality glasses for remote support during extracorporeal membrane oxygenation

Simon König, Niels Hinricher, Claus Backhaus
Computational and Structural Biotechnology Journal
Augmented Reality Applications
article

Usability evaluation of augmented reality glasses for remote support during extracorporeal membrane oxygenation

Simon König, Niels Hinricher, Claus Backhaus
article en

Abstract

Extracorporeal membrane oxygenation (ECMO) procedures may result in emergencies requiring the intervention of a perfusionist. However, their arrival results in waiting times that put patients at risk. Hence, nursing staff should be remotely supported using augmented reality (AR) in troubleshooting to improve patient safety. In this study, we aimed to investigate the usability of AR glasses <i>HMT-1</i> and <i>HoloLens 2</i> for remote support during ECMO and to determine the user acceptance of AR in intensive care. Ten nurses tested both glasses in a user test in randomized order under perfusionist guidance to rectify the three ECMO emergencies: a signal alert, a pump failure and reduced blood flow. An investigator rated their skills using a 3-step scheme, and success rates were calculated from the ratings and compared using the Wilcoxon test (α =.05). AR acceptance was assessed using the System Usability Scale (SUS) and User Experience Questionnaire (UEQ). We recorded 12 and 21 use errors with <i>HMT-1</i> and <i>HoloLens 2,</i> respectively. However, significantly fewer use errors occurred with the <i>HMT-1</i> than with <i>HoloLens 2</i> (Z = -1786, p = .046, n = 80) when troubleshooting the pump failure. Most participants rated <i>HoloLens 2</i> as more suitable. AR acceptance was rated as good with a SUS score of 72 (± 11). UEQ ratings for <i>attractiveness</i>, <i>dependability</i>, <i>stimulation</i>, <i>novelty</i>, and <i>efficiency</i> were excellent or good, while <i>perspicuity</i> was rated below average. The results indicate that both AR glasses are suitable for remote support; however, improvements to increase efficiency and patient safety in intensive care are necessary.

Computational and Structural Biotechnology JournalVol. 28
Technische Universität Berlin (DE), FH Münster University of Applied Sciences (DE)
Openalex Percentile: Top 75%
Augmented Reality Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Usability evaluation of augmented reality glasses for remote support during extracorporeal membrane oxygenation — Simon König, Niels Hinricher, et al. · Computational and Structural Biotechnology Journal (2025) | TGRS Research Map | TGRS