Comparative Study of Intensity Modulated Radiotherapy, Volumetric Modulated Arc Therapy versus Three Dimensional Radiotherapy in High Grade Glioma Patients

Back ground: In contrast to three-dimensional conformal radiotherapy (3DCRT), intensity-modulated radiotherapy (IMRT) improves dose homogeneity, conformity, and target volume coverage while delivering less radiation to normal brain tissue and organs at risk , such as the brainstem, optic nerves, optic chiasm, and brainstem. VMAT is an advanced radiation therapy method that administers radiation continuously while the treatment machine rotates around the patients. Methods: Planning data from 48 patients with high-grade glioma (HGG) were analyzed. The dose distribution for the CTV, PTV, and OAR was compared across three techniques—3D CRT, IMRT, and VMAT—using Dose Volume Histograms (DVHs) Results: We found the PTV coverage in terms of V95% was significantly higher in the VMAT and IMRT plans with values of 99.93 ± 0.12 and 99.49± 0.61 respectively compared to 98.23 ± 0.64 for the 3D-CRT plans Conclusion: the VMAT technique has proven better capability in reducing the radiation exposure to nearby healthy organs . Key words:3DCRT,IMRT,VMAT and HGG.

Authors

Institutions

Publication Details

Journal
Zagazig University Medical Journal
Published
2025-09-08
DOI
https://doi.org/10.21608/zumj.2025.402496.4045
Primary Topic
Glioma Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Study of Intensity Modulated Radiotherapy, Volumetric Modulated Arc Therapy versus Three Dimensional Radiotherapy in High Grade Glioma Patients

Nour Khalil, Ahmed Mohammed, Ahmed Obaya, Amira Hanna et al.
Zagazig University Medical Journal
Glioma Diagnosis and Treatment
article

Comparative Study of Intensity Modulated Radiotherapy, Volumetric Modulated Arc Therapy versus Three Dimensional Radiotherapy in High Grade Glioma Patients

Nour Khalil, Ahmed Mohammed, Ahmed Obaya, Amira Hanna, Nehal Gamal Elsayed, Esraa Mahmoud Mostafa
article en

Abstract

Back ground: In contrast to three-dimensional conformal radiotherapy (3DCRT), intensity-modulated radiotherapy (IMRT) improves dose homogeneity, conformity, and target volume coverage while delivering less radiation to normal brain tissue and organs at risk , such as the brainstem, optic nerves, optic chiasm, and brainstem. VMAT is an advanced radiation therapy method that administers radiation continuously while the treatment machine rotates around the patients. Methods: Planning data from 48 patients with high-grade glioma (HGG) were analyzed. The dose distribution for the CTV, PTV, and OAR was compared across three techniques—3D CRT, IMRT, and VMAT—using Dose Volume Histograms (DVHs) Results: We found the PTV coverage in terms of V95% was significantly higher in the VMAT and IMRT plans with values of 99.93 ± 0.12 and 99.49± 0.61 respectively compared to 98.23 ± 0.64 for the 3D-CRT plans Conclusion: the VMAT technique has proven better capability in reducing the radiation exposure to nearby healthy organs . Key words:3DCRT,IMRT,VMAT and HGG.

Zagazig University Medical JournalVol. 0(0)
Zagazig University (EG)
Openalex Percentile: Top 66%
Glioma Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.