From Wobble to Wisdom: Sharma-Devana PGI Modification of Hanging Loop Technique for Laparoscopic Peritoneal Dialysis Catheter Insertion

Background Continuous ambulatory peritoneal dialysis (CAPD) is widely used for ESKD, but catheter migration remains a major cause of malfunction. The Santosh-PGI Hanging Loop Technique, introduced in 2015, minimized the need for intracorporeal suturing and reduced migration. However, this technique was marred by difficult clip placement on the anterior abdominal wall and consequent catheter migration. We describe a novel modification to further enhance catheter stability. Materials and Methods Under general anesthesia, pneumoperitoneum was created via the Veress technique. A 5 mm camera and two 12 mm ports were employed, with the catheter placement port tunnelled obliquely for added anchorage. Initially, a modified epidural needle with a polypropylene loop was used; subsequently, the Carter-Thomason® Port Site needle facilitated easier passage of 2-0 polypropylene sutures around the catheter. Two snug subcutaneous loops were created to secure the catheter to the anterior abdominal wall while ensuring cuff positioning and catheter patency. Results Eight patients underwent the procedure with an average operative time of 37.5 minutes and negligible blood loss. All catheters remained functional without migration, malfunction, or omental entrapment during follow-up. Two catheters were removed for peritonitis at 8 and 18 months, unrelated to migration. The Carter-Thomason needle simplified fixation and reduced operative time compared to the epidural needle technique. Conclusion The Sharma-Devana PGI modification of the Hanging Loop Technique provides a reliable, minimally invasive solution to prevent CAPD catheter migration. It is reproducible, adaptable with locally available instruments, and may reduce the need for reoperations in patients with multiple comorbidities.

Authors

Institutions

Publication Details

Journal
Indian Journal of Nephrology
Published
2025-09-12
DOI
https://doi.org/10.25259/ijn_209_2025
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

From Wobble to Wisdom: Sharma-Devana PGI Modification of Hanging Loop Technique for Laparoscopic Peritoneal Dialysis Catheter Insertion

Rohit Sanjay Deshpande, Santosh Kumar, Sudheer Kumar Devana, Aditya Sharma
Indian Journal of Nephrology
Central Venous Catheters and Hemodialysis
article

From Wobble to Wisdom: Sharma-Devana PGI Modification of Hanging Loop Technique for Laparoscopic Peritoneal Dialysis Catheter Insertion

Rohit Sanjay Deshpande, Santosh Kumar, Sudheer Kumar Devana, Aditya Sharma
article en

Abstract

Background Continuous ambulatory peritoneal dialysis (CAPD) is widely used for ESKD, but catheter migration remains a major cause of malfunction. The Santosh-PGI Hanging Loop Technique, introduced in 2015, minimized the need for intracorporeal suturing and reduced migration. However, this technique was marred by difficult clip placement on the anterior abdominal wall and consequent catheter migration. We describe a novel modification to further enhance catheter stability. Materials and Methods Under general anesthesia, pneumoperitoneum was created via the Veress technique. A 5 mm camera and two 12 mm ports were employed, with the catheter placement port tunnelled obliquely for added anchorage. Initially, a modified epidural needle with a polypropylene loop was used; subsequently, the Carter-Thomason® Port Site needle facilitated easier passage of 2-0 polypropylene sutures around the catheter. Two snug subcutaneous loops were created to secure the catheter to the anterior abdominal wall while ensuring cuff positioning and catheter patency. Results Eight patients underwent the procedure with an average operative time of 37.5 minutes and negligible blood loss. All catheters remained functional without migration, malfunction, or omental entrapment during follow-up. Two catheters were removed for peritonitis at 8 and 18 months, unrelated to migration. The Carter-Thomason needle simplified fixation and reduced operative time compared to the epidural needle technique. Conclusion The Sharma-Devana PGI modification of the Hanging Loop Technique provides a reliable, minimally invasive solution to prevent CAPD catheter migration. It is reproducible, adaptable with locally available instruments, and may reduce the need for reoperations in patients with multiple comorbidities.

Indian Journal of NephrologyVol. 0
Post Graduate Institute of Medical Education and Research (IN)
Openalex Percentile: Top 61%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.