Investigation of the prediciton method for the active control force requirements

This paper takes the active-passive vibration isolation as the research object and the one DOF prediction method and the transfer function prediction method are studied to predict the active control force requirements. First the one DOF prediction method is introduced and the effect of the damping ratio of the isolation system on the active control force requirement is analyzed. Then the transfer function prediction method is put forward. A four-channel active-passive vibration isolation system model based on a flexible plate is built and its simulation results reveal that the transfer function prediction method is more accurate than the one DOF prediction method. Finally, vibration line spectra control experiments are conducted on a floating raft active-passive isolation device with two air compressors mounted. Active control forces are compared via the one DOF prediction method and the transfer function prediction method, as well as the experimental results. It is found that the tested output forces of the six actuators are greater than the prediction results via the one DOF prediction method, but close to the prediction results via the transfer function prediction method. It is concluded that the transfer function prediction method is more accurate for active control force prediction and helpful to guide engineering design.

Authors

Institutions

Publication Details

Published
2025-06-06
DOI
https://doi.org/10.1145/3760269.3760350
Primary Topic
Hydraulic and Pneumatic Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of the prediciton method for the active control force requirements

Feng Xiong, Neng Zhang, Yan Li
Hydraulic and Pneumatic Systems
article

Investigation of the prediciton method for the active control force requirements

Feng Xiong, Neng Zhang, Yan Li
article en

Abstract

This paper takes the active-passive vibration isolation as the research object and the one DOF prediction method and the transfer function prediction method are studied to predict the active control force requirements. First the one DOF prediction method is introduced and the effect of the damping ratio of the isolation system on the active control force requirement is analyzed. Then the transfer function prediction method is put forward. A four-channel active-passive vibration isolation system model based on a flexible plate is built and its simulation results reveal that the transfer function prediction method is more accurate than the one DOF prediction method. Finally, vibration line spectra control experiments are conducted on a floating raft active-passive isolation device with two air compressors mounted. Active control forces are compared via the one DOF prediction method and the transfer function prediction method, as well as the experimental results. It is found that the tested output forces of the six actuators are greater than the prediction results via the one DOF prediction method, but close to the prediction results via the transfer function prediction method. It is concluded that the transfer function prediction method is more accurate for active control force prediction and helpful to guide engineering design.

Naval University of Engineering (CN)
Openalex Percentile: Top 74%
Hydraulic and Pneumatic Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.