Comparative outcomes of parallel-wire and antegrade wire escalation techniques following single-wire failure in CTO PCI: A long-term follow-up study
Introduction/Objective. Following the failure of the single-wire technique in percutaneous coronary intervention (PCI) for chronic total occlusions (CTO), two principal antegrade escalation strategies are commonly employed: the parallel-wire technique and antegrade wire escalation (AWE). Despite their widespread use, comparative data on the procedural characteristics and long-term clinical outcomes of these strategies remain scarce. This study aims to compare the procedural parameters and long-term outcomes of the parallel-wire and AWE techniques after single-wire failure in CTO PCI. Methods. This retrospective, single-center study included patients who underwent successful CTO PCI between January 2018 and December 2023 using either the parallel-wire or AWE technique following single-wire failure. The primary endpoint was a composite of cardiac death, myocardial infarction, stroke, or target vessel revascularization (TVR). Secondary outcomes included procedure duration, fluoroscopy time, contrast volume, and total radiation dose. Median follow-up duration was 1222 days (IQR 580?1969 days). Results. Among 270 CTO PCI procedures, 112 (41.5%) required escalation: 90 with AWE and 22 with the parallel-wire technique. Baseline clinical and angiographic characteristics were comparable. The primary composite outcome occurred in 14.4% of the parallel-wire group and 9.1% of the AWE group (p = 0.73). No significant differences were observed in individual clinical events. Procedure duration was longer (95.5 ?} 43.6 vs. 77.0 ? 30.7 min; p = 0.064) and contrast volume higher (336.4 ? 113.3 vs. 271.6 ? 90.6 mL; p = 0.014) in the AWE group, with similar fluoroscopy time and radiation dose. No clinically or angiographically significant complications occurred during the periprocedural period. Conclusion. Both AWE and parallel-wire techniques demonstrate comparable safety and efficacy following single-wire failure in CTO PCI. While procedural efficiency slightly favored the parallel-wire strategy, overall outcomes support either approach, pending further prospective validation.
Authors
- Miodrag Ostojić (ORCID: https://orcid.org/0000-0002-1250-7461)
- Siniša Stojković (ORCID: https://orcid.org/0000-0002-5784-9377)
- Jovana Nikolajević Starčević
- Dejan Milašinović (ORCID: https://orcid.org/0000-0002-1528-5147)
- Miodrag Dikic
- Milan Dobrić (ORCID: https://orcid.org/0000-0001-7643-0451)
- Branko Beleslin (ORCID: https://orcid.org/0000-0001-9452-8241)
- Ivana Jovanović (ORCID: https://orcid.org/0000-0001-8036-6560)
- Milan Nedeljković (ORCID: https://orcid.org/0000-0002-1773-3054)
- Milorad Tešić (ORCID: https://orcid.org/0000-0002-3758-3719)
- Dejan Simeunović
- Vladimir Kanjuh
- Stefan Juričić (ORCID: https://orcid.org/0000-0002-3045-5263)
- Zlatko Mehmedbegović (ORCID: https://orcid.org/0000-0001-6400-1828)
- Marko Banović (ORCID: https://orcid.org/0000-0002-0017-6140)
- Jovana Klac
- Srdjan Aleksandic
Institutions
- Serbian Academy of Sciences and Arts (RS)
- University of Banja Luka (BA)
- University of Belgrade (RS)
- Centar za Promociju Nauke (RS)
- Institute for Cardiovascular Diseases of Vojvodina (RS)
- Institute of Physics Belgrade (RS)
Publication Details
- Journal
- Srpski arhiv za celokupno lekarstvo
- Published
- 2025-01-01
- DOI
- https://doi.org/10.2298/sarh250624073j
- Citations
- 1
- Primary Topic
- Integrated Circuits and Semiconductor Failure Analysis
- Type
- article
- Field-Weighted Citation Impact
- 0.73