Operando XCT with fine sampling of discharge process provides new insights into anode’s morphology evolution in a commercial zinc-air battery

Abstract Fine sampling of the discharge process revealed details of the anode’s morphology evolution in a commercial zinc-air battery. With special software developed for laboratory XCT scanners, it was possible to observe and quantify the evolution of individual particles. An operando sequence consisting of 30 tomograms within 30 h of discharge at a low C-rate, resulted in shape changes small enough for successful quantification. Two morphological descriptors, i.e. equivalent diameter and complexity factor, were used to assess the morphology of the particles. Details on underlying mechanisms are provided, including the shrinking-core concept, dissolution and the newly observed anisotropic shrinkage.

Authors

Institutions

Publication Details

Journal
Methods in microscopy
Published
2025-09-09
DOI
https://doi.org/10.1515/mim-2025-0007
Primary Topic
Electrochemical Analysis and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Operando XCT with fine sampling of discharge process provides new insights into anode’s morphology evolution in a commercial zinc-air battery

Hermann Tempel, Yasin Emre Durmus, Eunmi Im, Florian Hausen et al.
Methods in microscopy
Electrochemical Analysis and Applications
article

Operando XCT with fine sampling of discharge process provides new insights into anode’s morphology evolution in a commercial zinc-air battery

Hermann Tempel, Yasin Emre Durmus, Eunmi Im, Florian Hausen, Krzysztof Dzięcioł, Rüdiger‐A. Eichel
article en

Abstract

Abstract Fine sampling of the discharge process revealed details of the anode’s morphology evolution in a commercial zinc-air battery. With special software developed for laboratory XCT scanners, it was possible to observe and quantify the evolution of individual particles. An operando sequence consisting of 30 tomograms within 30 h of discharge at a low C-rate, resulted in shape changes small enough for successful quantification. Two morphological descriptors, i.e. equivalent diameter and complexity factor, were used to assess the morphology of the particles. Details on underlying mechanisms are provided, including the shrinking-core concept, dissolution and the newly observed anisotropic shrinkage.

Methods in microscopyVol. 2(3)
Forschungszentrum Jülich (DE), RWTH Aachen University (DE)
Bundesministerium für Bildung und Forschung
Openalex Percentile: Top 72%
Electrochemical Analysis and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.