Sensitive and Selective Electrochemical Detection of Hydrogen Peroxide Using a Silver-Incorporated CeO2/Ag2O Nanocomposite
Precision and real-time detection of hydrogen peroxide (H<sub>2</sub>O<sub>2</sub>) are essential in pharmaceutical, industrial, and defence sectors due to its strong oxidizing nature. In this study, silver (Ag)-doped CeO<sub>2</sub>/Ag<sub>2</sub>O-modified glassy carbon electrode (Ag-CeO<sub>2</sub>/Ag<sub>2</sub>O/GCE) has been developed as a non-enzymatic electrochemical sensor for the sensitive and selective detection of H<sub>2</sub>O<sub>2</sub>. The synthesized Ag-doped CeO<sub>2</sub>/Ag<sub>2</sub>O nanocomposite was characterized using various advanced techniques, including X-ray diffraction (XRD), Fourier-transform infrared spectroscopy (FT-IR), field-emission scanning electron microscopy (FE-SEM), and high-resolution transmission electron microscopy (HR-TEM). Their optical, magnetic, thermal, and chemical properties were further analyzed using UV-vis spectroscopy, electron paramagnetic resonance (EPR), thermogravimetric-differential thermal analysis (TG-DTA), and X-ray photoelectron spectroscopy (XPS). Electrochemical sensing performance was evaluated using cyclic voltammetry and amperometry. The Ag-CeO<sub>2</sub>/Ag<sub>2</sub>O/GCE exhibited superior electrocatalytic activity for H<sub>2</sub>O<sub>2</sub>, attributed to the increased number of active sites and enhanced electron transfer. The sensor displayed a high sensitivity of 2.728 µA cm<sup>-2</sup> µM<sup>-1</sup>, significantly outperforming the undoped CeO<sub>2</sub>/GCE (0.0404 µA cm<sup>-2</sup> µM<sup>-1</sup>). The limit of detection (LOD) and limit of quantification (LOQ) were found to be 6.34 µM and 21.1 µM, respectively, within a broad linear detection range of 1 × 10<sup>-8</sup> to 0.5 × 10<sup>-3</sup> M. The sensor also demonstrated excellent selectivity with minimal interference from common analytes, along with outstanding storage stability, reproducibility, and repeatability. Owing to these attributes, the Ag-CeO<sub>2</sub>/Ag<sub>2</sub>O/GCE sensor proved effective for real sample analysis, showcasing its potential as a reliable, non-enzymatic platform for H<sub>2</sub>O<sub>2</sub> detection.
Authors
- D. Krishnamoorthy (ORCID: https://orcid.org/0000-0001-9927-6864)
- Govindhasamy Murugadoss (ORCID: https://orcid.org/0000-0002-0972-2726)
- Shaik Gouse Peera (ORCID: https://orcid.org/0000-0002-2288-8800)
- Gunasekaran Manibalan (ORCID: https://orcid.org/0000-0001-9373-1483)
- Venkataraman Dharuman
Institutions
- National Institute of Technology Tiruchirappalli (IN)
- Alagappa University (IN)
- Indian Institute of Technology Bombay (IN)
- Sathyabama Institute of Science and Technology (IN)
- Keimyung University (KR)
Publication Details
- Journal
- Biosensors
- Published
- 2025-09-17
- DOI
- https://doi.org/10.3390/bios15090617
- Citations
- 1
- Primary Topic
- Electrochemical sensors and biosensors
- Type
- article
- Field-Weighted Citation Impact
- 0.73