Thermal characterization of lipid and aqueous layers on tear film

Tear film is composed of three layers: mucin, aqueous, and lipid; their integrity is essential for good eye function. A setup was implemented to acquire infrared image sequences from both eyes of each of the 48 participants, 23 with DED and 25 without it. The acquisition time and period were controlled to achieve a correct time scale in each blinking, and a spectral filter in the range of 9 to 10 μm was used to enhance the spectral resolution. The evaporation rate, related to the aqueous layer thickness, is computed by measuring energy on an infrared image sequence, observing that the exponential growth constantly changes with the thinnest of aqueous layers. When dry eye disease persists for a long time, the lipid layer becomes thicker, which can be characterized by a change in the thermal emissivity of the tear film. It is possible to evaluate the tear film integrity by changes in the energy emission in two blinking moments in an innocuous and efficient way. To corroborate the results, the infrared measurements were compared with measurements of tear meniscus height using a slit lamp and Schirmer tear test.

Authors

Institutions

Publication Details

Published
2025-09-17
DOI
https://doi.org/10.1117/12.3065711
Primary Topic
Ocular Surface and Contact Lens
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermal characterization of lipid and aqueous layers on tear film

P. Martínez-Torres, Arturo González-Vega, Sandra Mendoza, Francisco Javier Gantes-Nuñez et al.
Ocular Surface and Contact Lens
article

Thermal characterization of lipid and aqueous layers on tear film

P. Martínez-Torres, Arturo González-Vega, Sandra Mendoza, Francisco Javier Gantes-Nuñez, Paulo González, Carlos Villaseñor‐Mora
article en

Abstract

Tear film is composed of three layers: mucin, aqueous, and lipid; their integrity is essential for good eye function. A setup was implemented to acquire infrared image sequences from both eyes of each of the 48 participants, 23 with DED and 25 without it. The acquisition time and period were controlled to achieve a correct time scale in each blinking, and a spectral filter in the range of 9 to 10 μm was used to enhance the spectral resolution. The evaporation rate, related to the aqueous layer thickness, is computed by measuring energy on an infrared image sequence, observing that the exponential growth constantly changes with the thinnest of aqueous layers. When dry eye disease persists for a long time, the lipid layer becomes thicker, which can be characterized by a change in the thermal emissivity of the tear film. It is possible to evaluate the tear film integrity by changes in the energy emission in two blinking moments in an innocuous and efficient way. To corroborate the results, the infrared measurements were compared with measurements of tear meniscus height using a slit lamp and Schirmer tear test.

Universidad de Guanajuato (MX), Universidad Michoacana de San Nicolás de Hidalgo (MX)
Openalex Percentile: Top 66%
Ocular Surface and Contact Lens
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.