Video Transformer for Segmentation of Echocardiography Images in Myocardial Strain Measurement

The adoption of left ventricular global longitudinal strain (LVGLS) is still restricted by variability among various vendors and observers, despite advancements from tissue Doppler to speckle tracking imaging, machine learning, and, more recently, convolutional neural network (CNN)-based segmentation strain analysis. While CNNs have enabled fully automated strain measurement, they are inherently constrained by restricted receptive fields and a lack of temporal consistency. Transformer-based networks have emerged as a powerful alternative in medical imaging, offering enhanced global attention. Among these, the Video Swin Transformer (V-SwinT) architecture, with its 3D-shifted windows and locality inductive bias, is particularly well suited for ultrasound imaging, providing temporal consistency while optimizing computational efficiency. In this study, we propose the DTHR-SegStrain model based on a V-SwinT backbone. This model incorporates contour regression and utilizes an FCN-style multiscale feature fusion. As a result, it can generate accurate and temporally consistent left ventricle (LV) contours, allowing for direct calculation of myocardial strain without the need for conversion from segmentation to contours or any additional postprocessing. Compared to EchoNet-dynamic and Unity-GLS, DTHR-SegStrain showed greater efficiency, reliability, and validity in LVGLS measurements. Furthermore, the hybridization experiments assessed the interaction between segmentation models and strain algorithms, reinforcing that consistent segmentation contours over time can simplify strain calculations and decrease measurement variability. These findings emphasize the potential of V-SwinT-based frameworks to enhance the standardization and clinical applicability of LVGLS assessments.

Authors

Institutions

Publication Details

Journal
Journal of Imaging Informatics in Medicine
Published
2025-09-17
DOI
https://doi.org/10.1007/s10278-025-01682-5
Citations
1
Primary Topic
Cardiovascular Function and Risk Factors
Type
article
Field-Weighted Citation Impact
1.39

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Video Transformer for Segmentation of Echocardiography Images in Myocardial Strain Measurement

Donna Shu‐Han Lin, Lung‐Chun Lin, Lian‐Yu Lin, Geng-Shi Jeng et al.
1 citations
Journal of Imaging Informatics in Medicine
Cardiovascular Function and Risk Factors
1.39
article

Video Transformer for Segmentation of Echocardiography Images in Myocardial Strain Measurement

Donna Shu‐Han Lin, Lung‐Chun Lin, Lian‐Yu Lin, Geng-Shi Jeng, Ting‐Tse Lin, Cho‐Kai Wu, Chang-En Lin, Kuan‐Chih Huang
article en
1 citations

Abstract

The adoption of left ventricular global longitudinal strain (LVGLS) is still restricted by variability among various vendors and observers, despite advancements from tissue Doppler to speckle tracking imaging, machine learning, and, more recently, convolutional neural network (CNN)-based segmentation strain analysis. While CNNs have enabled fully automated strain measurement, they are inherently constrained by restricted receptive fields and a lack of temporal consistency. Transformer-based networks have emerged as a powerful alternative in medical imaging, offering enhanced global attention. Among these, the Video Swin Transformer (V-SwinT) architecture, with its 3D-shifted windows and locality inductive bias, is particularly well suited for ultrasound imaging, providing temporal consistency while optimizing computational efficiency. In this study, we propose the DTHR-SegStrain model based on a V-SwinT backbone. This model incorporates contour regression and utilizes an FCN-style multiscale feature fusion. As a result, it can generate accurate and temporally consistent left ventricle (LV) contours, allowing for direct calculation of myocardial strain without the need for conversion from segmentation to contours or any additional postprocessing. Compared to EchoNet-dynamic and Unity-GLS, DTHR-SegStrain showed greater efficiency, reliability, and validity in LVGLS measurements. Furthermore, the hybridization experiments assessed the interaction between segmentation models and strain algorithms, reinforcing that consistent segmentation contours over time can simplify strain calculations and decrease measurement variability. These findings emphasize the potential of V-SwinT-based frameworks to enhance the standardization and clinical applicability of LVGLS assessments.

Journal of Imaging Informatics in Medicine
National Yang Ming Chiao Tung University (TW), National Taiwan University (TW), National Taiwan University Hospital (TW), Memorial Hospital (US)
National Science and Technology Council
Openalex Percentile: Top 15%
Cardiovascular Function and Risk Factors
1.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.