Numerical and experimental investigation of TPMS-structured cold plates for electronic device cooling

With the increasing power of electronic chips, cold plates have emerged as a promising solution for cooling high thermal load electronic devices. Additive manufacturing facilitates the production of complex structures, expanding the possibilities for developing advanced designs. Triply Periodic Minimal Surface (TPMS) structures exhibit remarkable thermophysical properties, making them prominent candidates for heat transfer applications. This study numerically investigates the heat transfer capacity and flow characteristics of cold plates with serpentine channels and three TPMS structures, Diamond, Gyroid, and I-WP structures. From numerical results, the inherent mechanisms of TPMS structure strengthening heat transfer are analyzed from flow pattern and combined conduction and convection heat transfer. The results indicate that the Diamond structure exhibits the best overall thermohydraulic performance. The influence of two geometric parameters, porosity and unit cell size, on the thermohydraulic performance of TPMS structure, is examined. A TPMS structure with gradient changes in unit cell size in the direction from plate bottom to top is developed. At a pumping power below 2 W, its ultimate heat flux can exceed 256.9 W/cm 2 , improving the overall performance by 3.58 % to 6.24 % compared with the uniform one. Experimental results verify the reliability of numerical simulations, the maximum relative deviations in temperature, pressure drop, and heat transfer coefficient between numerical and test data were only 7.5 %, 13.9 % and, 5.44 %, respectively. • This paper presents a comprehensive modeling and thermohydraulic analysis of different TPMS-structured cold plates. • An evaluation is conducted to assess the effects of TPMS type, porosity, and unit cell size on thermohydraulic performance. • The inherent mechanisms of TPMS-enhanced heat transfer in cold plates are re-examined along the entire heat transfer path. • A cell size graded structure is proposed, achieving greater heat dissipation with minimal increase in pressure drop. • Experiments are conducted to validate the proposed models and findings.

Authors

Institutions

Publication Details

Journal
Applied Energy
Published
2025-09-17
DOI
https://doi.org/10.1016/j.apenergy.2025.126745
Citations
9
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
6.42
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical and experimental investigation of TPMS-structured cold plates for electronic device cooling

Xianhao Liu, Wen‐Quan Tao, Yuting Li, Junyu Chen et al.
9 citations
Applied Energy
Heat Transfer and Optimization
6.42
article

Numerical and experimental investigation of TPMS-structured cold plates for electronic device cooling

Xianhao Liu, Wen‐Quan Tao, Yuting Li, Junyu Chen, Xia‐Ting Feng, Junhong Chen, Haoning Zhu
article en
9 citations

Abstract

With the increasing power of electronic chips, cold plates have emerged as a promising solution for cooling high thermal load electronic devices. Additive manufacturing facilitates the production of complex structures, expanding the possibilities for developing advanced designs. Triply Periodic Minimal Surface (TPMS) structures exhibit remarkable thermophysical properties, making them prominent candidates for heat transfer applications. This study numerically investigates the heat transfer capacity and flow characteristics of cold plates with serpentine channels and three TPMS structures, Diamond, Gyroid, and I-WP structures. From numerical results, the inherent mechanisms of TPMS structure strengthening heat transfer are analyzed from flow pattern and combined conduction and convection heat transfer. The results indicate that the Diamond structure exhibits the best overall thermohydraulic performance. The influence of two geometric parameters, porosity and unit cell size, on the thermohydraulic performance of TPMS structure, is examined. A TPMS structure with gradient changes in unit cell size in the direction from plate bottom to top is developed. At a pumping power below 2 W, its ultimate heat flux can exceed 256.9 W/cm 2 , improving the overall performance by 3.58 % to 6.24 % compared with the uniform one. Experimental results verify the reliability of numerical simulations, the maximum relative deviations in temperature, pressure drop, and heat transfer coefficient between numerical and test data were only 7.5 %, 13.9 % and, 5.44 %, respectively. • This paper presents a comprehensive modeling and thermohydraulic analysis of different TPMS-structured cold plates. • An evaluation is conducted to assess the effects of TPMS type, porosity, and unit cell size on thermohydraulic performance. • The inherent mechanisms of TPMS-enhanced heat transfer in cold plates are re-examined along the entire heat transfer path. • A cell size graded structure is proposed, achieving greater heat dissipation with minimal increase in pressure drop. • Experiments are conducted to validate the proposed models and findings.

Applied EnergyVol. 401
Xi'an Jiaotong University (CN)
Openalex Percentile: Top 3%
Heat Transfer and Optimization
6.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.