Understanding how dielectric tube geometry impacts the atmospheric pressure plasma jet production of reactive oxygen and nitrogen species in water and in a poly(vinyl alcohol) hydrogel

Abstract This study investigates the influence of dielectric tube geometry on the production of reactive oxygen and nitrogen species (RONS) in water and in a poly(vinyl alcohol) (PVA) hydrogel. Plasma was generated using a pulsed-direct current (DC) power supply with quartz tubes of three different inner diameter (ID) (1 mm, 2 mm and 3 mm) and fixed outer diameter (4 mm). It was found that the larger (2 mm and 3 mm) ID tubes were more effective at producing RONS in water, whereas the smaller (1 mm) ID tube was more effective at producing RONS in the PVA hydrogel. These results show that larger ID tubes enhance plasma processes important for producing RONS in water but not for delivering RONS into soft materials such as the PVA hydrogel. This is because the PVA hydrogel was shown to present a significant barrier that inhibits the penetration of RONS during plasma jet treatment. Although the smaller 1 mm ID tube was not as time-efficient at producing RONS, other plasma processes such as gas flow dynamics and a more intense electric field through a confinement effect leads to a more focused plasma jet capable of penetrating the PVA hydrogel barrier. Therefore, considering factors such as the dielectric tube geometry of the plasma jet may be more important than assessing overall RONS production, which is usually measured in water, when developing plasma jets to deliver RONS into the subsurface of materials. These findings are useful in the future development of plasma jets and associated protocols for activation of hydrogels (in plasma activated hydrogel therapy, PAHT) or other applications such as treatment of solid cancer tumors.

Authors

Institutions

Publication Details

Journal
Journal of Physics D Applied Physics
Published
2025-09-17
DOI
https://doi.org/10.1088/1361-6463/ae07f2
Citations
1
Primary Topic
Plasma Applications and Diagnostics
Type
article
Field-Weighted Citation Impact
1.36

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Understanding how dielectric tube geometry impacts the atmospheric pressure plasma jet production of reactive oxygen and nitrogen species in water and in a poly(vinyl alcohol) hydrogel

Sushil Kumar KC, Bhagirath Ghimire, Sung‐Ha Hong, Endre J. Szili et al.
1 citations
Journal of Physics D Applied Physics
Plasma Applications and Diagnostics
1.36
article

Understanding how dielectric tube geometry impacts the atmospheric pressure plasma jet production of reactive oxygen and nitrogen species in water and in a poly(vinyl alcohol) hydrogel

Sushil Kumar KC, Bhagirath Ghimire, Sung‐Ha Hong, Endre J. Szili, Jun‐Seok Oh
article en
1 citations

Abstract

Abstract This study investigates the influence of dielectric tube geometry on the production of reactive oxygen and nitrogen species (RONS) in water and in a poly(vinyl alcohol) (PVA) hydrogel. Plasma was generated using a pulsed-direct current (DC) power supply with quartz tubes of three different inner diameter (ID) (1 mm, 2 mm and 3 mm) and fixed outer diameter (4 mm). It was found that the larger (2 mm and 3 mm) ID tubes were more effective at producing RONS in water, whereas the smaller (1 mm) ID tube was more effective at producing RONS in the PVA hydrogel. These results show that larger ID tubes enhance plasma processes important for producing RONS in water but not for delivering RONS into soft materials such as the PVA hydrogel. This is because the PVA hydrogel was shown to present a significant barrier that inhibits the penetration of RONS during plasma jet treatment. Although the smaller 1 mm ID tube was not as time-efficient at producing RONS, other plasma processes such as gas flow dynamics and a more intense electric field through a confinement effect leads to a more focused plasma jet capable of penetrating the PVA hydrogel barrier. Therefore, considering factors such as the dielectric tube geometry of the plasma jet may be more important than assessing overall RONS production, which is usually measured in water, when developing plasma jets to deliver RONS into the subsurface of materials. These findings are useful in the future development of plasma jets and associated protocols for activation of hydrogels (in plasma activated hydrogel therapy, PAHT) or other applications such as treatment of solid cancer tumors.

Journal of Physics D Applied PhysicsVol. 58(40)
University of South Australia (AU), Osaka Health Science University (JP), University of Alabama in Huntsville (US)
Medical Research Council
Openalex Percentile: Top 16%
Plasma Applications and Diagnostics
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.