Microdosimetric characterization of a clinical helium beam using a MicroPlus-Bridge detector and a diamond detector for RBE assessment

<i>Objective</i>. This study aims to perform a comprehensive microdosimetric characterization of a clinical helium ion beam at the Heidelberg ion-beam Therapy center, assessing radiation quality along a spread-out Bragg peak (SOBP) and providing experimental data to support the biological effectiveness of helium ions in clinical applications.<i>Approach</i>. Microdosimetric spectra were measured at several water depths within the SOBP using two solid-state detectors: a silicon and a synthetic single-crystal diamond detector. Microdosimetric quantities, including dose-mean lineal energy (yD) and frequency-mean lineal energy (yF), were derived. Monte Carlo simulations with the Geant4 toolkit replicated the experimental setup to validate the measured quantities. The modified microdosimetric kinetic model was also applied to estimate the relative biological effectiveness at 10% survival (RBE<sub>10</sub>). SAOS-2 and U2OS clonogenic assays were performed under identical irradiation conditions at the same facility to benchmark the RBE predictions.<i>Main results</i>. The experimental results demonstrated a progressive increase inyDvalues along the beam path, peaking at the distal edge of the SOBP, consistent with the simulated dose-averaged linear energy transfer distribution. The RBE<sub>10</sub>values estimated by the two solid-state detectors showed good agreement with the experimental data from clonogenic assays, within the associated uncertainties.<i>Significance</i>. These findings underscore the utility of advanced solid-state detectors for helium beam characterization and highlight the importance of microdosimetry in improving radiobiological modeling. The results provide further evidence supporting the clinical potential of helium ion therapy, particularly for tumors requiring high precision and maximal healthy tissue sparing.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2025-09-17
DOI
https://doi.org/10.1088/1361-6560/ae0862
Citations
2
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
3.04
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microdosimetric characterization of a clinical helium beam using a MicroPlus-Bridge detector and a diamond detector for RBE assessment

Mariacristina Guarrera, Valerio Cosimo Elia, C. Verona, A. Attili et al.
2 citations
Physics in Medicine and Biology
Radiation Therapy and Dosimetry
3.04
article

Microdosimetric characterization of a clinical helium beam using a MicroPlus-Bridge detector and a diamond detector for RBE assessment

Mariacristina Guarrera, Valerio Cosimo Elia, C. Verona, A. Attili, Giada Petringa, Thomas Tessonnier, Francesca Fede, Roberto Catalano, G.A.P. Cirrone, A. Kurmanova, Lorenzo Manti, Emilia Formicola, Yasmin Hamad, Andrea Mairani, Lorenzo Brighel
article en
2 citations

Abstract

<i>Objective</i>. This study aims to perform a comprehensive microdosimetric characterization of a clinical helium ion beam at the Heidelberg ion-beam Therapy center, assessing radiation quality along a spread-out Bragg peak (SOBP) and providing experimental data to support the biological effectiveness of helium ions in clinical applications.<i>Approach</i>. Microdosimetric spectra were measured at several water depths within the SOBP using two solid-state detectors: a silicon and a synthetic single-crystal diamond detector. Microdosimetric quantities, including dose-mean lineal energy (yD) and frequency-mean lineal energy (yF), were derived. Monte Carlo simulations with the Geant4 toolkit replicated the experimental setup to validate the measured quantities. The modified microdosimetric kinetic model was also applied to estimate the relative biological effectiveness at 10% survival (RBE<sub>10</sub>). SAOS-2 and U2OS clonogenic assays were performed under identical irradiation conditions at the same facility to benchmark the RBE predictions.<i>Main results</i>. The experimental results demonstrated a progressive increase inyDvalues along the beam path, peaking at the distal edge of the SOBP, consistent with the simulated dose-averaged linear energy transfer distribution. The RBE<sub>10</sub>values estimated by the two solid-state detectors showed good agreement with the experimental data from clonogenic assays, within the associated uncertainties.<i>Significance</i>. These findings underscore the utility of advanced solid-state detectors for helium beam characterization and highlight the importance of microdosimetry in improving radiobiological modeling. The results provide further evidence supporting the clinical potential of helium ion therapy, particularly for tumors requiring high precision and maximal healthy tissue sparing.

Physics in Medicine and BiologyVol. 70(19)
University of Rome Tor Vergata (IT), Istituto Nazionale di Fisica Nucleare (IT), German Cancer Research Center (DE), Heidelberg University (DE), University Hospital Heidelberg (DE), Istituto Nazionale di Fisica Nucleare, Sezione di Roma Tre (IT), Heidelberger Institut für Radioonkologie (DE), National Center for Oncological Hadrontherapy (IT), Istituto Nazionale di Fisica Nucleare, Sezione di Napoli (IT), National Center for Tumor Diseases (DE), Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud (IT), University of Campania "Luigi Vanvitelli" (IT), Istituto Nazionale di Fisica Nucleare, Sezione di Roma I (IT), University of Naples Federico II (IT)
Openalex Percentile: Top 8%
Radiation Therapy and Dosimetry
3.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.