High-Voltage Time-Domain Dielectric Response Characteristics Analysis of 72.5 kV Epoxy-Impregnated Dry-Type Bushings Under Different Moisture Contents

Epoxy-impregnated dry-type bushings are widely employed in high-voltage equipment, such as transformers, due to their excellent electric field regulation capability, oil-free design, and ease of maintenance. During actual operation, the crepe paper in the core of the bushing is susceptible to moisture absorption and dampness during production and service life, leading to a degradation of its insulation performance. Therefore, it is of critical importance to diagnose the moisture condition of dry-type bushings in a rapid, accurate, and nondestructive manner. In this study, three dry-type bushings with varying moisture contents were prepared, and their polarization and depolarization current (PDC) characteristics un-der different voltage levels were measured. The results indicate that the PDC characteristics of the bushing with varying moisture contents exhibit significant differences. Under the same voltage, as the moisture content increases, both the polarization current and depolarization current of the bushing increase markedly. Furthermore, the bushing with high moisture content demonstrates electrical conductivity comparable to that of an electrolyte, with the steady-state polarization current reaching up to $1.35 \times 10^{-6} \mathrm{~A}$ at the maximum. This study provides an experimental basis for assessing the moisture condition of epoxy-impregnated dry-type bushings.

Authors

Institutions

Publication Details

Published
2025-07-18
DOI
https://doi.org/10.1109/icceee63357.2025.11156303
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-Voltage Time-Domain Dielectric Response Characteristics Analysis of 72.5 kV Epoxy-Impregnated Dry-Type Bushings Under Different Moisture Contents

Zengfeng Di, Wei Chen, Lei Liu, Xiaoling Yang et al.
High voltage insulation and dielectric phenomena
article

High-Voltage Time-Domain Dielectric Response Characteristics Analysis of 72.5 kV Epoxy-Impregnated Dry-Type Bushings Under Different Moisture Contents

Zengfeng Di, Wei Chen, Lei Liu, Xiaoling Yang, Yanqing Niu, Jiacong Li
article en

Abstract

Epoxy-impregnated dry-type bushings are widely employed in high-voltage equipment, such as transformers, due to their excellent electric field regulation capability, oil-free design, and ease of maintenance. During actual operation, the crepe paper in the core of the bushing is susceptible to moisture absorption and dampness during production and service life, leading to a degradation of its insulation performance. Therefore, it is of critical importance to diagnose the moisture condition of dry-type bushings in a rapid, accurate, and nondestructive manner. In this study, three dry-type bushings with varying moisture contents were prepared, and their polarization and depolarization current (PDC) characteristics un-der different voltage levels were measured. The results indicate that the PDC characteristics of the bushing with varying moisture contents exhibit significant differences. Under the same voltage, as the moisture content increases, both the polarization current and depolarization current of the bushing increase markedly. Furthermore, the bushing with high moisture content demonstrates electrical conductivity comparable to that of an electrolyte, with the steady-state polarization current reaching up to $1.35 \times 10^{-6} \mathrm{~A}$ at the maximum. This study provides an experimental basis for assessing the moisture condition of epoxy-impregnated dry-type bushings.

Chongqing University (CN), He University (CN), Yalong Hydro (China) (CN)
Openalex Percentile: Top 81%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

High-Voltage Time-Domain Dielectric Response Characteristics Analysis of 72.5 kV Epoxy-Impregnated Dry-Type Bushings Under Different Moisture Contents — Zengfeng Di, Wei Chen, et al. · (2025) | TGRS Research Map | TGRS