Improved Current Limiter for Expanding Grid-forming Modular Multilevel Converters Operation Area

Grid-forming modular multilevel converters (MMCs) require a higher overload capacity during grid faults. However, the traditional circular limiters are only designed to restrict the peak of the AC-side current without considering the arm current characteristics of MMC, leading the waste of arm current margin. In this paper, the regularity between the arm current and the AC voltage is analyzed, restricting the peak of the precise arm current limiting can enable the converter to output more active and reactive power. Furthermore, by injecting second-harmonic component to suppress the maximum of arm current, the proposed improved current limiter can further increase the reactive power generation of MMC, reducing the voltage drop of AC voltage and active power limit. The effectiveness of the improved current limiter is proved in MATLAB/Simulink.

Authors

Institutions

Publication Details

Published
2025-07-18
DOI
https://doi.org/10.1109/icceee63357.2025.11156792
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improved Current Limiter for Expanding Grid-forming Modular Multilevel Converters Operation Area

Chengquan Yang, Zheng Gong, Yi‐Feng Su, Ruofei Yang
HVDC Systems and Fault Protection
article

Improved Current Limiter for Expanding Grid-forming Modular Multilevel Converters Operation Area

Chengquan Yang, Zheng Gong, Yi‐Feng Su, Ruofei Yang
article en

Abstract

Grid-forming modular multilevel converters (MMCs) require a higher overload capacity during grid faults. However, the traditional circular limiters are only designed to restrict the peak of the AC-side current without considering the arm current characteristics of MMC, leading the waste of arm current margin. In this paper, the regularity between the arm current and the AC voltage is analyzed, restricting the peak of the precise arm current limiting can enable the converter to output more active and reactive power. Furthermore, by injecting second-harmonic component to suppress the maximum of arm current, the proposed improved current limiter can further increase the reactive power generation of MMC, reducing the voltage drop of AC voltage and active power limit. The effectiveness of the improved current limiter is proved in MATLAB/Simulink.

China University of Mining and Technology (CN)
Openalex Percentile: Top 75%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.