On-site Partial Discharge Detection Using Pulse Current Method for Collective Capacitors

As an important reactive power compensation equipment in the substation, collective capacitors are of great significance to the safe and stable operation of the power grid. However, the large capacity of collective capacitors reduces the sensitivity of local discharge detection and increases the capacity requirements of the test equipment. This paper proposes a method of optimizing the design of detection impedance and suppressing loop interference, which can improve the sensitivity of partial discharge detection by pulsed current method and makes the minimum detectable discharge meet the test requirements. Through theoretical analysis and experimental research, the equivalence of partial discharge test under low frequency 5Hz and industrial frequency 50Hz is verified, and a low-frequency partial discharge on-site detection program is designed, which is successfully applied in the substation site. In this paper, the method reduces the capacity of the compensation reactor and the test power demand and realizes the partial discharge field detection of the aggregate capacitor.

Authors

Institutions

Publication Details

Published
2025-07-04
DOI
https://doi.org/10.1109/icpet66029.2025.11160501
Primary Topic
Sensor Technology and Measurement Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On-site Partial Discharge Detection Using Pulse Current Method for Collective Capacitors

X. Li, Feng Ye, Li Quan, Zitao Zheng et al.
Sensor Technology and Measurement Systems
article

On-site Partial Discharge Detection Using Pulse Current Method for Collective Capacitors

X. Li, Feng Ye, Li Quan, Zitao Zheng, Na Zhao
article en

Abstract

As an important reactive power compensation equipment in the substation, collective capacitors are of great significance to the safe and stable operation of the power grid. However, the large capacity of collective capacitors reduces the sensitivity of local discharge detection and increases the capacity requirements of the test equipment. This paper proposes a method of optimizing the design of detection impedance and suppressing loop interference, which can improve the sensitivity of partial discharge detection by pulsed current method and makes the minimum detectable discharge meet the test requirements. Through theoretical analysis and experimental research, the equivalence of partial discharge test under low frequency 5Hz and industrial frequency 50Hz is verified, and a low-frequency partial discharge on-site detection program is designed, which is successfully applied in the substation site. In this paper, the method reduces the capacity of the compensation reactor and the test power demand and realizes the partial discharge field detection of the aggregate capacitor.

State Grid Corporation of China (China) (CN), Shanghai Electric (China) (CN)
Openalex Percentile: Top 71%
Sensor Technology and Measurement Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.