Weak Distribution Network Fault Characteristic Analysis and Validation

Rural distribution networks exhibit inherent vulnerabilities characterized by extensive coverage with long supply lines, limited load capacity, and low automation levels, which collectively compromise fault diagnosis and management capabilities, thereby severely constraining power supply reliability. The high penetration of distributed generation (DG) further exacerbates these challenges by introducing diverse fault scenarios with variable characteristics, notably rendering conventional three-stage overcurrent protection methods ineffective. This necessitates urgent development of fault diagnosis solutions for rural networks lacking high-precision synchrophasor measurements. This paper establishes an equivalent fault model for small hydropower plants incorporating excitation control response and investigates the impact of DG integration on fault signatures in weak distribution networks. Given that the negative-sequence network is unaffected by DG penetration, a novel area protection method based on comparative analysis of boundary negative-sequence components is proposed. This approach enables accurate short-circuit fault diagnosis in critical protection zones while minimizing infrastructure upgrade costs. The effectiveness of the proposed method is validated with simulation case studies.

Authors

Institutions

Publication Details

Published
2025-07-04
DOI
https://doi.org/10.1109/icpet66029.2025.11160483
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Weak Distribution Network Fault Characteristic Analysis and Validation

Zhaoru Han, Yuanliang Fan, Xiaobin Wang, Xinghua Huang
Power Systems Fault Detection
article

Weak Distribution Network Fault Characteristic Analysis and Validation

Zhaoru Han, Yuanliang Fan, Xiaobin Wang, Xinghua Huang
article en

Abstract

Rural distribution networks exhibit inherent vulnerabilities characterized by extensive coverage with long supply lines, limited load capacity, and low automation levels, which collectively compromise fault diagnosis and management capabilities, thereby severely constraining power supply reliability. The high penetration of distributed generation (DG) further exacerbates these challenges by introducing diverse fault scenarios with variable characteristics, notably rendering conventional three-stage overcurrent protection methods ineffective. This necessitates urgent development of fault diagnosis solutions for rural networks lacking high-precision synchrophasor measurements. This paper establishes an equivalent fault model for small hydropower plants incorporating excitation control response and investigates the impact of DG integration on fault signatures in weak distribution networks. Given that the negative-sequence network is unaffected by DG penetration, a novel area protection method based on comparative analysis of boundary negative-sequence components is proposed. This approach enables accurate short-circuit fault diagnosis in critical protection zones while minimizing infrastructure upgrade costs. The effectiveness of the proposed method is validated with simulation case studies.

University of Jinan (CN), Fujian Electric Power Survey & Design Institute (CN)
Openalex Percentile: Top 69%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.