Analysis of Current Unbalance of 500kV Parallel Cables

In recent years, in order to reduce the cost of equipment and technical constraints, the use of same-phase parallel cable power supply is also increasing, not only to save land, but also to increase the transmission capacity. Due to the parallel operation of multiple cables, the problem of unbalance between cables gradually appears, affecting the stability and security of the system. This paper analyzes the unbalanced degree of 500kV shunt cable, finds out the general law of the change of unbalanced degree, and calculates the specific influence that the change of typical factors will have on the unbalanced degree. This article simulates the unbalance of 500kV parallel cables, analyzes various factors that affect their unbalance, and proposes arrangement suggestions and measures to reduce unbalance.

Authors

Institutions

Publication Details

Published
2025-07-04
DOI
https://doi.org/10.1109/icpet66029.2025.11160366
Primary Topic
Railway Systems and Energy Efficiency
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Current Unbalance of 500kV Parallel Cables

Haiyong Long, Dawei Zang, Wanlin Quan, Jue Zhang et al.
Railway Systems and Energy Efficiency
article

Analysis of Current Unbalance of 500kV Parallel Cables

Haiyong Long, Dawei Zang, Wanlin Quan, Jue Zhang, Jiahao Wen, Jiayin Bian, Meng Wang, Yan Xu, Jinhao Zhang
article en

Abstract

In recent years, in order to reduce the cost of equipment and technical constraints, the use of same-phase parallel cable power supply is also increasing, not only to save land, but also to increase the transmission capacity. Due to the parallel operation of multiple cables, the problem of unbalance between cables gradually appears, affecting the stability and security of the system. This paper analyzes the unbalanced degree of 500kV shunt cable, finds out the general law of the change of unbalanced degree, and calculates the specific influence that the change of typical factors will have on the unbalanced degree. This article simulates the unbalance of 500kV parallel cables, analyzes various factors that affect their unbalance, and proposes arrangement suggestions and measures to reduce unbalance.

Taishan Medical University (CN), China Southern Power Grid (China) (CN)
Openalex Percentile: Top 65%
Railway Systems and Energy Efficiency
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.