Electroosmotic hydraulic-based haptic reproduction of human pulse with high accuracy for remote diagnosis

Haptic pulse reproduction technology enables physicians to conduct remote, contact-free pulse diagnosis by transcending temporal and spatial constraints in traditional medical practice. However, current systems face challenges in accurately reproducing realistic pulse haptic feedback, which impacts diagnostic reliability. Here, we developed an electroosmotic hydraulic-based pulse haptic reproduction interface (PHRI) system that can precisely reproduce realistic haptic information of the human pulse. This PHRI system demonstrates the rapid response and precise control of electroosmotic hydraulics, achieving a frequency response of 500 Hz and an output force of 100 mN at 160 V driving voltage. Besides, time-domain and frequency-domain analyses further confirm high accuracy, with a correlation coefficient of 0.99 between reproduced and actual pulses. When tested under varying pressures, the PHRI system shows a small root mean square error of <1 Pa in frequency spectra. This PHRI technology provides a robust platform for remote pulse diagnosis and advances the integration of traditional Chinese medicine with telemedicine systems.

Authors

Institutions

Publication Details

Journal
Microsystems & Nanoengineering
Published
2025-09-16
DOI
https://doi.org/10.1038/s41378-025-01042-x
Primary Topic
Geophysics and Sensor Technology
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electroosmotic hydraulic-based haptic reproduction of human pulse with high accuracy for remote diagnosis

Xiongying Ye, Houde Liu, Fei Tang, Yuanyuan Liu et al.
Microsystems & Nanoengineering
Geophysics and Sensor Technology
article

Electroosmotic hydraulic-based haptic reproduction of human pulse with high accuracy for remote diagnosis

Xiongying Ye, Houde Liu, Fei Tang, Yuanyuan Liu, Huaiyi Chen, Wentai Deng, Kangkang Dong, Xiaohao Wang
article en

Abstract

Haptic pulse reproduction technology enables physicians to conduct remote, contact-free pulse diagnosis by transcending temporal and spatial constraints in traditional medical practice. However, current systems face challenges in accurately reproducing realistic pulse haptic feedback, which impacts diagnostic reliability. Here, we developed an electroosmotic hydraulic-based pulse haptic reproduction interface (PHRI) system that can precisely reproduce realistic haptic information of the human pulse. This PHRI system demonstrates the rapid response and precise control of electroosmotic hydraulics, achieving a frequency response of 500 Hz and an output force of 100 mN at 160 V driving voltage. Besides, time-domain and frequency-domain analyses further confirm high accuracy, with a correlation coefficient of 0.99 between reproduced and actual pulses. When tested under varying pressures, the PHRI system shows a small root mean square error of <1 Pa in frequency spectra. This PHRI technology provides a robust platform for remote pulse diagnosis and advances the integration of traditional Chinese medicine with telemedicine systems.

Microsystems & NanoengineeringVol. 11(1)
Tsinghua University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 69%
Geophysics and Sensor Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Electroosmotic hydraulic-based haptic reproduction of human pulse with high accuracy for remote diagnosis — Xiongying Ye, Houde Liu, et al. · Microsystems & Nanoengineering (2025) | TGRS Research Map | TGRS