Two-step automated method for robust Fourier ptychographic microscopy LED misalignment calibration

• We propose a novel automatic LED calibration method for Fourier Ptychographic Microscopy (FPM). • Proposed calibration method is a simple and easy to implement method for hardware calibration of LED in FPM. • Our method shows improved reconstruction when compared to numerical LED position correction. • It is purely hardware calibration method and does not require any special equipement or algorithms. • It does not require any special calibration test targets and can be done with most samples This article introduces a fully automated and robust hardware calibration method for aligning the LED matrix in Fourier Ptychographic Microscopy (FPM). The proposed method is divided into two independent procedures targeting translational and rotational misalignments. Translational errors are corrected using the Automatic LED Calibration (ALC) metric, which evaluates the symmetry of Fourier spectra obtained from two images illuminated from opposite angles. Rotational misalignments are handled through a subpixel image registration algorithm that estimates direction and magnitude of the angular deviation. Neither step requires specialized calibration targets or complex modeling. Experimental results confirm that method reliably compensates for a wide range of misalignments, delivering stable and reproducible outcomes across diverse conditions and calibration objects. This dual-step approach significantly reduces alignment effort and improves the quality of image reconstruction. Once calibrated, the system enables high-fidelity reconstructions using both Quasi-Newton and Gerchberg-Saxton algorithms. The method is compatible with open-source platforms like FPMapp, streamlining its integration into existing workflows. By simplifying system alignment while maintaining precision, this calibration strategy is poised to accelerate the broader adoption of FPM in digital pathology and biomedical imaging. The proposed approach is presented as a step-by-step procedure suitable even for non-expert users, facilitating practical implementation across various applications.

Authors

Institutions

Publication Details

Journal
Optics and Lasers in Engineering
Published
2025-09-16
DOI
https://doi.org/10.1016/j.optlaseng.2025.109340
Citations
1
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
1.88
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Two-step automated method for robust Fourier ptychographic microscopy LED misalignment calibration

Piotr Arcab, Mikołaj Rogalski, Piotr Zdańkowski, Maciej Trusiak
1 citations
Optics and Lasers in Engineering
Advanced X-ray Imaging Techniques
1.88
article

Two-step automated method for robust Fourier ptychographic microscopy LED misalignment calibration

Piotr Arcab, Mikołaj Rogalski, Piotr Zdańkowski, Maciej Trusiak
article en
1 citations

Abstract

• We propose a novel automatic LED calibration method for Fourier Ptychographic Microscopy (FPM). • Proposed calibration method is a simple and easy to implement method for hardware calibration of LED in FPM. • Our method shows improved reconstruction when compared to numerical LED position correction. • It is purely hardware calibration method and does not require any special equipement or algorithms. • It does not require any special calibration test targets and can be done with most samples This article introduces a fully automated and robust hardware calibration method for aligning the LED matrix in Fourier Ptychographic Microscopy (FPM). The proposed method is divided into two independent procedures targeting translational and rotational misalignments. Translational errors are corrected using the Automatic LED Calibration (ALC) metric, which evaluates the symmetry of Fourier spectra obtained from two images illuminated from opposite angles. Rotational misalignments are handled through a subpixel image registration algorithm that estimates direction and magnitude of the angular deviation. Neither step requires specialized calibration targets or complex modeling. Experimental results confirm that method reliably compensates for a wide range of misalignments, delivering stable and reproducible outcomes across diverse conditions and calibration objects. This dual-step approach significantly reduces alignment effort and improves the quality of image reconstruction. Once calibrated, the system enables high-fidelity reconstructions using both Quasi-Newton and Gerchberg-Saxton algorithms. The method is compatible with open-source platforms like FPMapp, streamlining its integration into existing workflows. By simplifying system alignment while maintaining precision, this calibration strategy is poised to accelerate the broader adoption of FPM in digital pathology and biomedical imaging. The proposed approach is presented as a step-by-step procedure suitable even for non-expert users, facilitating practical implementation across various applications.

Optics and Lasers in EngineeringVol. 195
Warsaw University of Technology (PL)
Openalex Percentile: Top 13%
Advanced X-ray Imaging Techniques
1.88
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.