Novel SIMPAP for Primary Treatment of Respiratory Distress in Premature Neonates— A Randomized Controlled Trial

Background Preterm neonates are often born with respiratory distress requiring continuous distending pressure respiratory support. Nasal continuous positive airway pressure (CPAP) devices favor a good outcome when initiated early. In our country, most preterm babies are born in healthcare setups that are not equipped to offer CPAP support at birth. The failure to initiate the appropriate treatment in the initial hours could have cascading effects on the outcome. A portable, low-flow driven, non-electrical device, simple continuous positive airway pressure (SIMPAP) [Patent no. 201841018247—Indian PTO] was developed and tested in an earlier in vitro study. The present study was done to compare the efficacy and safety of SIMPAP against bubble CPAP when used as primary support in preterm respiratory distress syndrome (RDS). Methods This was a randomized controlled non-inferiority trial conducted among 60 neonates between 28 and 37 weeks of gestation admitted with respiratory distress. The intervention group was initiated on SIMPAP support, and the control group on bubble CPAP. The outcome measured was the change in saturation oxygen pressure index (SOPI) over 6 h. Results The SOPI in the CPAP group was 1.150 (1.070-1.408), and in the SIMPAP group was 1.080 (1.060-1.501). The difference between the SOPI measured at recruitment and 6 h in the CPAP group was 0.020 (−0.001 to 0.213) and in the SIMPAP group was 0.010 (0.000-0.030), P = 0.847. SOPI at the end of 72 h was 1.07 (1.05-1.07) and 1.05 (1.05) in the control and intervention groups, respectively. The complications between the two groups were not statistically significant. Conclusion The efficacy and safety of SIMPAP are similar to bubble CPAP in the first 6 h and up to 72 h for treating respiratory distress in preterm neonates.

Authors

Institutions

Publication Details

Journal
Journal of Neonatology
Published
2025-09-16
DOI
https://doi.org/10.1177/09732179251375569
Primary Topic
Neonatal Respiratory Health Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel SIMPAP for Primary Treatment of Respiratory Distress in Premature Neonates— A Randomized Controlled Trial

Sushma Krishnegowda, Srinivasa Murthy Doreswamy, Deepti Thandaveshwar
Journal of Neonatology
Neonatal Respiratory Health Research
article

Novel SIMPAP for Primary Treatment of Respiratory Distress in Premature Neonates— A Randomized Controlled Trial

Sushma Krishnegowda, Srinivasa Murthy Doreswamy, Deepti Thandaveshwar
article en

Abstract

Background Preterm neonates are often born with respiratory distress requiring continuous distending pressure respiratory support. Nasal continuous positive airway pressure (CPAP) devices favor a good outcome when initiated early. In our country, most preterm babies are born in healthcare setups that are not equipped to offer CPAP support at birth. The failure to initiate the appropriate treatment in the initial hours could have cascading effects on the outcome. A portable, low-flow driven, non-electrical device, simple continuous positive airway pressure (SIMPAP) [Patent no. 201841018247—Indian PTO] was developed and tested in an earlier in vitro study. The present study was done to compare the efficacy and safety of SIMPAP against bubble CPAP when used as primary support in preterm respiratory distress syndrome (RDS). Methods This was a randomized controlled non-inferiority trial conducted among 60 neonates between 28 and 37 weeks of gestation admitted with respiratory distress. The intervention group was initiated on SIMPAP support, and the control group on bubble CPAP. The outcome measured was the change in saturation oxygen pressure index (SOPI) over 6 h. Results The SOPI in the CPAP group was 1.150 (1.070-1.408), and in the SIMPAP group was 1.080 (1.060-1.501). The difference between the SOPI measured at recruitment and 6 h in the CPAP group was 0.020 (−0.001 to 0.213) and in the SIMPAP group was 0.010 (0.000-0.030), P = 0.847. SOPI at the end of 72 h was 1.07 (1.05-1.07) and 1.05 (1.05) in the control and intervention groups, respectively. The complications between the two groups were not statistically significant. Conclusion The efficacy and safety of SIMPAP are similar to bubble CPAP in the first 6 h and up to 72 h for treating respiratory distress in preterm neonates.

Journal of NeonatologyVol. 40(1)
JSS Academy of Higher Education and Research (IN), McMaster University (CA)
Openalex Percentile: Top 64%
Neonatal Respiratory Health Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.