Binary pseudo-random array for calibration of imaging optical microscopes

Imaging systems are crucial in various fields, and extracting accurate information from raw images is essential. However, real-world limitations affect image data quality. Therefore, thoroughly understanding imaging system performance and developing techniques to improve data accuracy remains a major challenge. To develop a technology for quantitative calibration and correction of image processing imperfections that is applicable to any imaging system without hardware changes, we introduce and validate a binary pseudo-random array (BPRA) test artifact. The fabricated BPRA test artifact is designed to create a contrast pattern with binary reflectance or transmission that is suitable for Instrument Transfer Function (ITF) characterization of optical imaging microscopes. We have demonstrated the efficacy of BPRA test artifacts to characterize the resolution limit and the geometrical distortion of a Nikon MM-800/L optical microscope and have used a highly-randomized array (HRA) to measure the ITF of a Zeiss Elyra 7 microscope and reconstruct images of yeast cells. We found that the frequency response of the Zeiss microscope exhibits complex behavior beyond Gaussian approximation, emphasizing the importance of empirical ITF characterization. In this respect, the Power Spectral Density (PSD) of an HRA measurement (after correction for sampling due to the detector pixel size) provides an empirical function for the microscope ITF, even in the absence of an imaging model. If one seeks to understand how different microscope settings impact the ITF, the BPRA provides a comprehensive answer in a single measurement. Thus, proof-of-principle efficacy and the value of the BPRA test artifacts developed for optical microscopy were successfully demonstrated.

Authors

Institutions

Publication Details

Published
2025-09-16
DOI
https://doi.org/10.1117/12.3065489
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Binary pseudo-random array for calibration of imaging optical microscopes

Ian Lacey, Simon Rochester, Behzad Lame Rad, Valeriy V. Yashchuk et al.
Optical measurement and interference techniques
article

Binary pseudo-random array for calibration of imaging optical microscopes

Ian Lacey, Simon Rochester, Behzad Lame Rad, Valeriy V. Yashchuk, Adam Schwartzberg, Scott Dhuey, Keiko Munechika, Peter Z. Takacs, Nicolas P. Smith, Kaito Yamada
article en

Abstract

Imaging systems are crucial in various fields, and extracting accurate information from raw images is essential. However, real-world limitations affect image data quality. Therefore, thoroughly understanding imaging system performance and developing techniques to improve data accuracy remains a major challenge. To develop a technology for quantitative calibration and correction of image processing imperfections that is applicable to any imaging system without hardware changes, we introduce and validate a binary pseudo-random array (BPRA) test artifact. The fabricated BPRA test artifact is designed to create a contrast pattern with binary reflectance or transmission that is suitable for Instrument Transfer Function (ITF) characterization of optical imaging microscopes. We have demonstrated the efficacy of BPRA test artifacts to characterize the resolution limit and the geometrical distortion of a Nikon MM-800/L optical microscope and have used a highly-randomized array (HRA) to measure the ITF of a Zeiss Elyra 7 microscope and reconstruct images of yeast cells. We found that the frequency response of the Zeiss microscope exhibits complex behavior beyond Gaussian approximation, emphasizing the importance of empirical ITF characterization. In this respect, the Power Spectral Density (PSD) of an HRA measurement (after correction for sampling due to the detector pixel size) provides an empirical function for the microscope ITF, even in the absence of an imaging model. If one seeks to understand how different microscope settings impact the ITF, the BPRA provides a comprehensive answer in a single measurement. Thus, proof-of-principle efficacy and the value of the BPRA test artifacts developed for optical microscopy were successfully demonstrated.

Lawrence Berkeley National Laboratory (US)
Openalex Percentile: Top 75%
Optical measurement and interference techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.