Dual-Chronoamperometry Drift Correction for Electrochemical Sensors

Accurate sensing of biomolecular targets is crucial for diagnosing diseases and developing technologies for personalized medicine. However, measuring biomarker levels with high precision is often challenging due to signal drift caused by biofouling and monolayer instability. We demonstrate a novel continuous dual-chronoamperometry method with faradaic current extraction to enable accurate and reliable detection of biomarkers in the presence of drift. We apply two sequential chronoamperometry pulses, a reference (-500 mV) and a test (+500 mV), to capture all capacitive and faradaic currents in the range. In the absence of the target, the drift in the reference and test currents is multilinear, and this relationship can be used to predict the contribution of the target current. As a proof-of-concept, we demonstrate that signal drift can be corrected using our molecular pendulum for IFN-γ detection. Importantly, we show that this technique is broadly applicable to other amperometry-based systems such as a monolayer transporter sensor, an electrochemical DNA sensor, and electrochemical aptamer-based sensors. Moreover, we train a linear regression machine learning model and use its error to quantify target concentrations with dual-chronoamperometry data. This novel method enhances the reliability and sensitivity of chronoamperometry, paving the way for its application in real-time monitoring scenarios.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2025-09-16
DOI
https://doi.org/10.1021/acssensors.5c02104
Citations
3
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
2.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dual-Chronoamperometry Drift Correction for Electrochemical Sensors

Fatemeh Esmaeili, Jagotamoy Das, Shana O. Kelley, Maria D. Cabezas et al.
3 citations
ACS Sensors
Analytical Chemistry and Sensors
2.21
article

Dual-Chronoamperometry Drift Correction for Electrochemical Sensors

Fatemeh Esmaeili, Jagotamoy Das, Shana O. Kelley, Maria D. Cabezas, Mohammed Eslami, Connor D. Flynn, Edward Hartley Sargent, Kimberly T. Riordan, Vuslat B. Juska, Dingran Chang, Zhenwei Wu, Kefan Yang, Scott E. Isaacson, Ethan Brazelton, Ashley Copenhaver
article en
3 citations

Abstract

Accurate sensing of biomolecular targets is crucial for diagnosing diseases and developing technologies for personalized medicine. However, measuring biomarker levels with high precision is often challenging due to signal drift caused by biofouling and monolayer instability. We demonstrate a novel continuous dual-chronoamperometry method with faradaic current extraction to enable accurate and reliable detection of biomarkers in the presence of drift. We apply two sequential chronoamperometry pulses, a reference (-500 mV) and a test (+500 mV), to capture all capacitive and faradaic currents in the range. In the absence of the target, the drift in the reference and test currents is multilinear, and this relationship can be used to predict the contribution of the target current. As a proof-of-concept, we demonstrate that signal drift can be corrected using our molecular pendulum for IFN-γ detection. Importantly, we show that this technique is broadly applicable to other amperometry-based systems such as a monolayer transporter sensor, an electrochemical DNA sensor, and electrochemical aptamer-based sensors. Moreover, we train a linear regression machine learning model and use its error to quantify target concentrations with dual-chronoamperometry data. This novel method enhances the reliability and sensitivity of chronoamperometry, paving the way for its application in real-time monitoring scenarios.

ACS SensorsVol. 10(9)
Northwestern University (US), McCormick Theological Seminary (US), University of Toronto (CA), University College Cork (IE), Weinberg Medical Physics (United States) (US), Northeastern Technical College (US), Tyndall Centre (GB), International Institute for Nanotechnology
Openalex Percentile: Top 11%
Analytical Chemistry and Sensors
2.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.