Measuring ejecta particle size distributions using dark-field imaging versus light-field imaging

The characterization of ejecta particle size distributions from shock-loaded metals has significant interest to National Laboratories. Traditional measurement techniques have employed holography, Mie scattering, and low-energy X-ray imaging. Recent advancements in optical diagnostics have demonstrated that dark-field (Schlieren) imaging enhances the contrast of ejecta images by emphasizing high-frequency spatial information, thereby improving particle detection and size distribution measurements. To achieve simultaneous light-field and dark-field imaging, an optical system has been designed to split the ejecta motions onto two independent cameras. This configuration enables the concurrent recording of both conventional light-field images and dark-field images, facilitating a comprehensive analysis of ejecta dynamics. High-speed imaging sequences will be utilized to capture the temporal evolution of ejecta dispersal, providing critical insight into the underlying physical mechanisms. Dark-field imaging is particularly advantageous in that it suppresses coherent laser artifacts, such as mode structures and speckle, which can obscure fine-scale features in recorded images. The imaging system is configured such that the ejecta volume is illuminated by a high-intensity laser source. A Fourier optical relay system introduces a well-defined spatial stop, where incident laser light is focused onto an absorbing element, preventing direct illumination from reaching the imaging sensor. As a result, the camera records only scattered light, enhancing contrast and enabling improved particle size discrimination. A 50/50 beam splitter directs a portion of the light to a secondary camera, allowing for the simultaneous acquisition of light-field images. An additional benefit to using dark field imaging occurs when optimizing the alignment of complex optical imaging systems. Alignment set up time is greatly reduced. However, this approach necessitates direct access to the Fourier plane stop position. Analyzing the astigmatism of an optical imaging system is much easier in dark field imaging mode.

Authors

Publication Details

Published
2025-09-16
DOI
https://doi.org/10.1117/12.3065366
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measuring ejecta particle size distributions using dark-field imaging versus light-field imaging

Eloisa Zepeda‐Alarcon, Amy E. Lewis, Morris I. Kaufman, Katherine Walters et al.
Flow Measurement and Analysis
article

Measuring ejecta particle size distributions using dark-field imaging versus light-field imaging

Eloisa Zepeda‐Alarcon, Amy E. Lewis, Morris I. Kaufman, Katherine Walters, R. C. Malone, Lakhena Raingsan, Jesus J. Castaneda
article en

Abstract

The characterization of ejecta particle size distributions from shock-loaded metals has significant interest to National Laboratories. Traditional measurement techniques have employed holography, Mie scattering, and low-energy X-ray imaging. Recent advancements in optical diagnostics have demonstrated that dark-field (Schlieren) imaging enhances the contrast of ejecta images by emphasizing high-frequency spatial information, thereby improving particle detection and size distribution measurements. To achieve simultaneous light-field and dark-field imaging, an optical system has been designed to split the ejecta motions onto two independent cameras. This configuration enables the concurrent recording of both conventional light-field images and dark-field images, facilitating a comprehensive analysis of ejecta dynamics. High-speed imaging sequences will be utilized to capture the temporal evolution of ejecta dispersal, providing critical insight into the underlying physical mechanisms. Dark-field imaging is particularly advantageous in that it suppresses coherent laser artifacts, such as mode structures and speckle, which can obscure fine-scale features in recorded images. The imaging system is configured such that the ejecta volume is illuminated by a high-intensity laser source. A Fourier optical relay system introduces a well-defined spatial stop, where incident laser light is focused onto an absorbing element, preventing direct illumination from reaching the imaging sensor. As a result, the camera records only scattered light, enhancing contrast and enabling improved particle size discrimination. A 50/50 beam splitter directs a portion of the light to a secondary camera, allowing for the simultaneous acquisition of light-field images. An additional benefit to using dark field imaging occurs when optimizing the alignment of complex optical imaging systems. Alignment set up time is greatly reduced. However, this approach necessitates direct access to the Fourier plane stop position. Analyzing the astigmatism of an optical imaging system is much easier in dark field imaging mode.

Openalex Percentile: Top 71%
Flow Measurement and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Measuring ejecta particle size distributions using dark-field imaging versus light-field imaging — Eloisa Zepeda‐Alarcon, Amy E. Lewis, et al. · (2025) | TGRS Research Map | TGRS