A highly stable and flexible ion-selective patch sensor for real-time sweat Na+ and K+ monitoring

Abstract Wearable electrochemical biosensors based on solid-contact ion-selective electrodes (SC-ISEs) have emerged as a promising platform for non-invasive, real-time monitoring of sweat electrolytes. However, conventional ion-selective biosensors often suffer from potential drift and long-term instability due to the formation of undesired aqueous layers and interference from other ions. To overcome these challenges, we present a flexible and highly stable SC-ISE patch sensor for simultaneous detection of Na⁺ and K⁺ ions in sweat. The sensor employs a laser-induced graphene (LIG) electrode patterned directly onto a Ti 3 C 2 T x -MXene/PVDF nanofiber mat, which was fabricated using electrospinning followed by CO 2 laser carbonization. The MPNFs/LIG@TiO 2 hybrid structure exhibits excellent electrical conductivity, high electrochemical surface area, and enhanced hydrophobicity, all contributing to reduced potential drift and improved signal stability. Ion-selective membranes (ISMs) based on a PVC-SEBS blend were drop-cast onto the LIG electrode to achieve selective ion recognition, while a double-sided PET tape substrate ensured mechanical flexibility and skin conformity. The addition of TiO 2 nanoparticles during the thermal laser oxidation process induced π-π interactions within the composite, resulting in a robust 3D porous electrode architecture with enhanced ion transport and interfacial contact. The fabricated Na + and K + sensors demonstrated near-Nernstian sensitivities of 48.8 mV/decade and 50.5 mV/decade, respectively, within physiologically relevant sweat concentration ranges. Additionally, the sensors showed excellent long-term stability with minimal potential drift (0.04 mV/h for Na + and 0.08 mV/h for K + ), along with rapid response and high accuracy. The use of scalable, low-cost laser engraving and solution casting techniques enables reliable batch fabrication, making the proposed sensor patch a strong candidate for integration into wearable platforms aimed at continuous electrolyte monitoring during physical activity.

Authors

Institutions

Publication Details

Journal
Micro and Nano Systems Letters
Published
2025-09-12
DOI
https://doi.org/10.1186/s40486-025-00235-3
Citations
2
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
1.47
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A highly stable and flexible ion-selective patch sensor for real-time sweat Na+ and K+ monitoring

Md Selim Reza, Md. Zahidul Islam, Jae Yeong Park, Dong Yun Kim et al.
2 citations
Micro and Nano Systems Letters
Analytical Chemistry and Sensors
1.47
article

A highly stable and flexible ion-selective patch sensor for real-time sweat Na+ and K+ monitoring

Md Selim Reza, Md. Zahidul Islam, Jae Yeong Park, Dong Yun Kim, J Go, Ahmad Abdus Samad
article en
2 citations

Abstract

Abstract Wearable electrochemical biosensors based on solid-contact ion-selective electrodes (SC-ISEs) have emerged as a promising platform for non-invasive, real-time monitoring of sweat electrolytes. However, conventional ion-selective biosensors often suffer from potential drift and long-term instability due to the formation of undesired aqueous layers and interference from other ions. To overcome these challenges, we present a flexible and highly stable SC-ISE patch sensor for simultaneous detection of Na⁺ and K⁺ ions in sweat. The sensor employs a laser-induced graphene (LIG) electrode patterned directly onto a Ti 3 C 2 T x -MXene/PVDF nanofiber mat, which was fabricated using electrospinning followed by CO 2 laser carbonization. The MPNFs/LIG@TiO 2 hybrid structure exhibits excellent electrical conductivity, high electrochemical surface area, and enhanced hydrophobicity, all contributing to reduced potential drift and improved signal stability. Ion-selective membranes (ISMs) based on a PVC-SEBS blend were drop-cast onto the LIG electrode to achieve selective ion recognition, while a double-sided PET tape substrate ensured mechanical flexibility and skin conformity. The addition of TiO 2 nanoparticles during the thermal laser oxidation process induced π-π interactions within the composite, resulting in a robust 3D porous electrode architecture with enhanced ion transport and interfacial contact. The fabricated Na + and K + sensors demonstrated near-Nernstian sensitivities of 48.8 mV/decade and 50.5 mV/decade, respectively, within physiologically relevant sweat concentration ranges. Additionally, the sensors showed excellent long-term stability with minimal potential drift (0.04 mV/h for Na + and 0.08 mV/h for K + ), along with rapid response and high accuracy. The use of scalable, low-cost laser engraving and solution casting techniques enables reliable batch fabrication, making the proposed sensor patch a strong candidate for integration into wearable platforms aimed at continuous electrolyte monitoring during physical activity.

Micro and Nano Systems LettersVol. 13(1)
Kwangwoon University (KR)
Openalex Percentile: Top 16%
Analytical Chemistry and Sensors
1.47
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.