The impact of a disinfection intervention on the microbial indoor air quality at a university library

Introduction: Indoor environment contributes to human health and productivity. The absence of climatic control systems may lead to microbial contamination. The air quality of public institutions should be monitored. Therefore, this study was conducted to determine the microbial load of the air in the main library at the University of Guyana and to evaluate the effectiveness of a disinfection intervention on the microbial load of the air. Materials and methods: This was an experimental- observational study involving three phases: analyzing the microbial quality of the air, a disinfection experiment, and a disinfection intervention. Phase 1 was done before the rehabilitation of the library, Phase 2 was done during the rehabilitation, and Phase 3 was carried out after the rehabilitation and the disinfection intervention. Samples were collected on settle plates and incubated. Colony- Forming Units (CFUs) were enumerated and the microbial load was determined using a standardised equation. Several disinfectants were tested against two bacteria and a specific disinfection protocol was developed for the disinfection intervention. Results: The bacterial load for Phase 1 (13,114 CFU/m3) and Phase 2 (7,636 CFU/m3) was higher than that of Phase 3 (4,648 CFU/m3). There was an extremely high fungal load (4,067 CFU/m3) before the disinfection intervention but no growth after. Conclusion: We concluded that a high microbial load was found in our study before the disinfection intervention which was considerably diminished after the intervention. We recommend implementing the cleaning regimen we developed as part of the library’s cleaning protocol.

Authors

Institutions

Publication Details

Journal
Journal of Air Pollution and Health
Published
2025-09-12
DOI
https://doi.org/10.18502/japh.v10i3.19600
Primary Topic
Conservation Techniques and Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The impact of a disinfection intervention on the microbial indoor air quality at a university library

Ede Tyrell, Andrew Hutson, Obena Vanlewin, Bibi Rafeena Ally Charles et al.
Journal of Air Pollution and Health
Conservation Techniques and Studies
article

The impact of a disinfection intervention on the microbial indoor air quality at a university library

Ede Tyrell, Andrew Hutson, Obena Vanlewin, Bibi Rafeena Ally Charles, Kevin Hohenkirk
article en

Abstract

Introduction: Indoor environment contributes to human health and productivity. The absence of climatic control systems may lead to microbial contamination. The air quality of public institutions should be monitored. Therefore, this study was conducted to determine the microbial load of the air in the main library at the University of Guyana and to evaluate the effectiveness of a disinfection intervention on the microbial load of the air. Materials and methods: This was an experimental- observational study involving three phases: analyzing the microbial quality of the air, a disinfection experiment, and a disinfection intervention. Phase 1 was done before the rehabilitation of the library, Phase 2 was done during the rehabilitation, and Phase 3 was carried out after the rehabilitation and the disinfection intervention. Samples were collected on settle plates and incubated. Colony- Forming Units (CFUs) were enumerated and the microbial load was determined using a standardised equation. Several disinfectants were tested against two bacteria and a specific disinfection protocol was developed for the disinfection intervention. Results: The bacterial load for Phase 1 (13,114 CFU/m3) and Phase 2 (7,636 CFU/m3) was higher than that of Phase 3 (4,648 CFU/m3). There was an extremely high fungal load (4,067 CFU/m3) before the disinfection intervention but no growth after. Conclusion: We concluded that a high microbial load was found in our study before the disinfection intervention which was considerably diminished after the intervention. We recommend implementing the cleaning regimen we developed as part of the library’s cleaning protocol.

Journal of Air Pollution and Health
Westmorland General Hospital (GB), University of Guyana (GY)
Openalex Percentile: Top 69%
Conservation Techniques and Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.