Construction of an Electrochemical Impedance Spectroscopy Matching Method Based on Adaptive Multi-Error Driving and Application Testing for Biofilm Impedance Verification

Electrochemical impedance spectroscopy (EIS) is a technique used to analyze the kinetics and interfacial processes of electrochemical systems. The selection of an appropriate equivalent circuit model for EIS interpretation was traditionally reliant on expert experience, rendering the process subjective and prone to error. To address these limitations, an automated framework for both model selection and parameter estimation was proposed. The methodology was structured such that initial model screening was performed by a global heuristic search algorithm, adaptive optimization was guided by an integrated XGBoost-based error feedback mechanism, and precise parameter estimation was achieved using a Differential Evolution-Levenberg-Marquardt (DE-LM) algorithm. When evaluated on a purpose-built dataset comprising 4.8 × 10<sup>5</sup> spectra across diverse circuit and biofilm scenarios, a model classification accuracy of 96.32% was achieved, and a 72.3% reduction in parameter estimation error was recorded. The practical utility of the method was validated through the quantitative analysis of bovine serum albumin-Clenbuterol hydrochloride (BSA-CLB), wherein an accuracy of 95.2% was demonstrated and a strong linear correlation with target concentration (R<sup>2</sup> = 0.999) was found. Through this approach, the limitations of traditional black-box models were mitigated by resolving the physical meaning of parameters. Consequently, the automated and quantitative monitoring of processes such as biofilm formation was facilitated, enabling the efficient evaluation of antimicrobial drugs or anti-fouling coatings.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2025-09-12
DOI
https://doi.org/10.3390/bios15090604
Citations
2
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
1.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Construction of an Electrochemical Impedance Spectroscopy Matching Method Based on Adaptive Multi-Error Driving and Application Testing for Biofilm Impedance Verification

Hu Bao, Peter Dai, Fan Yu, Ying Xu et al.
2 citations
Biosensors
Advanced Chemical Sensor Technologies
1.35
article

Construction of an Electrochemical Impedance Spectroscopy Matching Method Based on Adaptive Multi-Error Driving and Application Testing for Biofilm Impedance Verification

Hu Bao, Peter Dai, Fan Yu, Ying Xu, Boyu Guo
article en
2 citations

Abstract

Electrochemical impedance spectroscopy (EIS) is a technique used to analyze the kinetics and interfacial processes of electrochemical systems. The selection of an appropriate equivalent circuit model for EIS interpretation was traditionally reliant on expert experience, rendering the process subjective and prone to error. To address these limitations, an automated framework for both model selection and parameter estimation was proposed. The methodology was structured such that initial model screening was performed by a global heuristic search algorithm, adaptive optimization was guided by an integrated XGBoost-based error feedback mechanism, and precise parameter estimation was achieved using a Differential Evolution-Levenberg-Marquardt (DE-LM) algorithm. When evaluated on a purpose-built dataset comprising 4.8 × 10<sup>5</sup> spectra across diverse circuit and biofilm scenarios, a model classification accuracy of 96.32% was achieved, and a 72.3% reduction in parameter estimation error was recorded. The practical utility of the method was validated through the quantitative analysis of bovine serum albumin-Clenbuterol hydrochloride (BSA-CLB), wherein an accuracy of 95.2% was demonstrated and a strong linear correlation with target concentration (R<sup>2</sup> = 0.999) was found. Through this approach, the limitations of traditional black-box models were mitigated by resolving the physical meaning of parameters. Consequently, the automated and quantitative monitoring of processes such as biofilm formation was facilitated, enabling the efficient evaluation of antimicrobial drugs or anti-fouling coatings.

BiosensorsVol. 15(9)
Wenzhou University (CN), Hangzhou Dianzi University (CN)
Openalex Percentile: Top 17%
Advanced Chemical Sensor Technologies
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Construction of an Electrochemical Impedance Spectroscopy Matching Method Based on Adaptive Multi-Error Driving and Application Testing for Biofilm Impedance Verification — Hu Bao, Peter Dai, et al. · Biosensors (2025) | TGRS Research Map | TGRS