Effects of WC Addition on Microstructure and Properties of Plasma-Cladded AlCoCrFeNi High-Entropy Alloy Coatings

In order to enhance the performance of 20# steel, this study successfully fabricated AlCoCrFeNi high-entropy alloy coatings with different WC contents (x = 0, 10, 20, 30 wt%) on its surface using plasma cladding technology. The effects of WC content on the microstructure, mechanical properties, and corrosion resistance of the coatings were systematically investigated. The results indicate that without WC addition, the coating consists of a dual-phase structure comprising BCC and FCC phases. With the incorporation of WC, the FCC phase disappears, and the coating evolves into a composite structure based on the BCC matrix, embedded with multiple carbide phases such as W2C, M7C3, MxCγ, and Co6W6C. These carbides are predominantly distributed along grain boundaries. As the WC content increases, significant grain refinement occurs and the volume fraction of carbides rises. The coating exhibits a mixed microstructure of equiaxed and columnar crystals, with excellent metallurgical bonding to the substrate. The microhardness of the coating increases markedly with higher WC content; however, the rate of enhancement slows when WC exceeds 20 wt%. The hardness of 1066.36 HV is achieved at 30 wt% WC. Wear test results show that both the friction coefficient and wear rate first decrease and then increase with increasing WC content. The optimal wear resistance is observed at 20 wt% WC, with a friction coefficient of 0.549 and a wear mass loss of only 0.25 mg, representing an approximately 40% reduction compared to the WC-free coating. Electrochemical tests demonstrate that the coating with 20 wt% WC facilitates the formation of a dense and stable passive film in NaCl solution, effectively inhibiting Cl− ion penetration. This coating exhibits the best corrosion resistance, characterized by the lowest corrosion current density of 1.349 × 10−6 A·cm−2 and the highest passive film resistance of 2764 Ω·cm2.

Authors

Institutions

Publication Details

Journal
Lubricants
Published
2025-09-12
DOI
https://doi.org/10.3390/lubricants13090407
Citations
1
Primary Topic
High Entropy Alloys Studies
Type
article
Field-Weighted Citation Impact
0.71
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of WC Addition on Microstructure and Properties of Plasma-Cladded AlCoCrFeNi High-Entropy Alloy Coatings

Yuanyuan Zeng, Zhengbing Meng, Ouyang Yongzhong, Juangang Zhao et al.
1 citations
Lubricants
High Entropy Alloys Studies
0.71
article

Effects of WC Addition on Microstructure and Properties of Plasma-Cladded AlCoCrFeNi High-Entropy Alloy Coatings

Yuanyuan Zeng, Zhengbing Meng, Ouyang Yongzhong, Juangang Zhao, Tiansheng Li, Wen Cai Xu, Xinbin Liu, Jiasheng Qing
article en
1 citations

Abstract

In order to enhance the performance of 20# steel, this study successfully fabricated AlCoCrFeNi high-entropy alloy coatings with different WC contents (x = 0, 10, 20, 30 wt%) on its surface using plasma cladding technology. The effects of WC content on the microstructure, mechanical properties, and corrosion resistance of the coatings were systematically investigated. The results indicate that without WC addition, the coating consists of a dual-phase structure comprising BCC and FCC phases. With the incorporation of WC, the FCC phase disappears, and the coating evolves into a composite structure based on the BCC matrix, embedded with multiple carbide phases such as W2C, M7C3, MxCγ, and Co6W6C. These carbides are predominantly distributed along grain boundaries. As the WC content increases, significant grain refinement occurs and the volume fraction of carbides rises. The coating exhibits a mixed microstructure of equiaxed and columnar crystals, with excellent metallurgical bonding to the substrate. The microhardness of the coating increases markedly with higher WC content; however, the rate of enhancement slows when WC exceeds 20 wt%. The hardness of 1066.36 HV is achieved at 30 wt% WC. Wear test results show that both the friction coefficient and wear rate first decrease and then increase with increasing WC content. The optimal wear resistance is observed at 20 wt% WC, with a friction coefficient of 0.549 and a wear mass loss of only 0.25 mg, representing an approximately 40% reduction compared to the WC-free coating. Electrochemical tests demonstrate that the coating with 20 wt% WC facilitates the formation of a dense and stable passive film in NaCl solution, effectively inhibiting Cl− ion penetration. This coating exhibits the best corrosion resistance, characterized by the lowest corrosion current density of 1.349 × 10−6 A·cm−2 and the highest passive film resistance of 2764 Ω·cm2.

LubricantsVol. 13(9)
Guilin University of Technology (CN), University of South China (CN), Hunan Institute of Technology (CN)
Openalex Percentile: Top 27%
High Entropy Alloys Studies
0.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.