Antibacterial Activity of a Trace-Cu-Modified Mg Alloy in Simulated Intestinal Fluid

Mg alloys hold promise for biodegradable gastrointestinal implants, but most evaluations rely on simplified media like Hank's solution, which lacks organic components and fails to replicate the acidic-to-alkaline transition of intestinal fluid, risking underestimation of biodegradation rates and clinical relevance. This work investigated a trace-Cu-modified Mg alloy (Mg-0.05Cu) in simulated intestinal fluid (SIF) versus Hank's solution. Microstructural analysis confirmed Mg<sub>2</sub>Cu intermetallic phases as Cu reservoirs. Electrochemical and immersion tests revealed significantly accelerated biodegradation in SIF, due to its disruption of protective layer formation, sustaining loose biodegradation products. The biodegradation rate of the trace-Cu-modified Mg alloy in SIF was consistent with reported values for Mg alloys in similar media, as was that in Hank's solution. Remarkably, Mg-0.05Cu exhibited potent antibacterial activity against <i>E. coli</i>, achieving 99.3% eradication within 12 h and 100% elimination by 24-48 h, alongside excellent cytocompatibility with L929 cells (>95% viability). This efficacy arose from the synergistic Cu<sup>2+</sup> release and high-pH microenvironment. These findings demonstrate that trace Cu alloying in high-purity Mg balances rapid antibacterial action with controlled biodegradation in a physiologically relevant SIF. This positions Mg-0.05Cu as a highly promising candidate for practical applications, such as biodegradable intestinal stents, anti-adhesion barriers, anastomosis rings, and anti-obesity devices, where rapid infection control and predictable degradation are critical for clinical success. This work underscores the importance of using biomimetic media for evaluating gastrointestinal implants and establishes Mg-0.05Cu as a promising strategy for developing infection-resistant biodegradable devices.

Authors

Institutions

Publication Details

Journal
Journal of Functional Biomaterials
Published
2025-09-12
DOI
https://doi.org/10.3390/jfb16090344
Citations
1
Primary Topic
Nanomaterials for catalytic reactions
Type
article
Field-Weighted Citation Impact
0.94
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Antibacterial Activity of a Trace-Cu-Modified Mg Alloy in Simulated Intestinal Fluid

Zhongyan Wei, Ming‐Chun Zhao, Lan Ying Jiang, Yi Yao et al.
1 citations
Journal of Functional Biomaterials
Nanomaterials for catalytic reactions
0.94
article

Antibacterial Activity of a Trace-Cu-Modified Mg Alloy in Simulated Intestinal Fluid

Zhongyan Wei, Ming‐Chun Zhao, Lan Ying Jiang, Yi Yao, Baiyun Zhong, Xin Li, Jinping Li, Weidong Liu, Manli Zhou
article en
1 citations

Abstract

Mg alloys hold promise for biodegradable gastrointestinal implants, but most evaluations rely on simplified media like Hank's solution, which lacks organic components and fails to replicate the acidic-to-alkaline transition of intestinal fluid, risking underestimation of biodegradation rates and clinical relevance. This work investigated a trace-Cu-modified Mg alloy (Mg-0.05Cu) in simulated intestinal fluid (SIF) versus Hank's solution. Microstructural analysis confirmed Mg<sub>2</sub>Cu intermetallic phases as Cu reservoirs. Electrochemical and immersion tests revealed significantly accelerated biodegradation in SIF, due to its disruption of protective layer formation, sustaining loose biodegradation products. The biodegradation rate of the trace-Cu-modified Mg alloy in SIF was consistent with reported values for Mg alloys in similar media, as was that in Hank's solution. Remarkably, Mg-0.05Cu exhibited potent antibacterial activity against <i>E. coli</i>, achieving 99.3% eradication within 12 h and 100% elimination by 24-48 h, alongside excellent cytocompatibility with L929 cells (>95% viability). This efficacy arose from the synergistic Cu<sup>2+</sup> release and high-pH microenvironment. These findings demonstrate that trace Cu alloying in high-purity Mg balances rapid antibacterial action with controlled biodegradation in a physiologically relevant SIF. This positions Mg-0.05Cu as a highly promising candidate for practical applications, such as biodegradable intestinal stents, anti-adhesion barriers, anastomosis rings, and anti-obesity devices, where rapid infection control and predictable degradation are critical for clinical success. This work underscores the importance of using biomimetic media for evaluating gastrointestinal implants and establishes Mg-0.05Cu as a promising strategy for developing infection-resistant biodegradable devices.

Journal of Functional BiomaterialsVol. 16(9)
Central South University (CN), Chinese PLA General Hospital (CN), First Affiliated Hospital of Chinese PLA General Hospital (CN), Xiangya Hospital Central South University (CN)
Openalex Percentile: Top 22%
Nanomaterials for catalytic reactions
0.94
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.