Multimodal synergistic thermometry: designing wide-range optical thermometers <i>via</i> Eu<sup>3+</sup>/Er<sup>3+</sup> co-doped YVO<sub>4</sub>
In this paper, a five-mode synergistic thermometry system based on Eu<sup>3+</sup>/Er<sup>3+</sup> co-doped YVO<sub>4</sub> fluorescent material was developed. By utilizing the spectral properties of the phosphor, two luminescence intensity ratio (LIR) and two excitation intensity ratio (EIR) thermometry modes were established, and the luminescence lifetime thermometry (<i>τ</i>) mode of Eu<sup>3+ 5</sup>D<sub>0</sub> → <sup>7</sup>F<sub>2</sub> was also introduced into this system. The <i>S</i><sub>r</sub> values of both Er<sup>3+</sup>- and Eu<sup>3+</sup>/Er<sup>3+</sup>-based LIR modes decrease with increasing temperature, and the maximal value of <i>S</i><sub>r</sub> (<i>S</i><sub>rmax</sub>) is 0.98% K<sup>-1</sup> at 300 K. Similarly, the EIR mode <i>via</i> V-O charge transfer (monitoring Er<sup>3+</sup> emissions) shows a declining <i>S</i><sub>r</sub> trend, and the <i>S</i><sub>rmax</sub> of the EIR mode <i>via</i> V-O charge transfer (monitoring Er<sup>3+</sup> emissions) is 1.01% K<sup>-1</sup> at 300 K. Unlike conventional LIR systems, the EIR mode based on Eu<sup>3+</sup> (<sup>7</sup>F<sub>0</sub> → <sup>5</sup>D<sub>4</sub>/<sup>7</sup>F<sub>0</sub> → <sup>5</sup>L<sub>6</sub>) exhibits a distinctly different temperature dependence in its <i>S</i><sub>r</sub> value, and at 500 K the <i>S</i><sub>rmax</sub> of <i>S</i><sub>r</sub> of YVO<sub>4</sub>:Eu<sup>3+</sup>,Er<sup>3+</sup> can reach 0.65% K<sup>-1</sup>. The <i>S</i><sub>rmax</sub> of the <i>τ</i> mode can reach 0.71% K<sup>-1</sup> at 500 K, which is superior to that of other systems. Notably, the EIR and <i>τ</i> modes address the limited high-temperature sensitivity of Boltzmann-type thermometry. In short, the YVO<sub>4</sub>:Eu<sup>3+</sup>,Er<sup>3+</sup> phosphor exhibits excellent thermometric performance and application potential.
Authors
- Lu He (ORCID: https://orcid.org/0000-0002-9733-3949)
- Xiaoli Wu (ORCID: https://orcid.org/0009-0006-6087-2558)
- Ziyuan Li (ORCID: https://orcid.org/0000-0001-8029-9804)
- Liang Qiao (ORCID: https://orcid.org/0000-0002-8982-5636)
Institutions
- Guilin University of Aerospace Technology (CN)
- Guilin University of Technology (CN)
- Guilin University of Electronic Technology (CN)
Publication Details
- Journal
- Dalton Transactions
- Published
- 2025-01-01
- DOI
- https://doi.org/10.1039/d5dt01830g
- Citations
- 1
- Primary Topic
- Calibration and Measurement Techniques
- Type
- article
- Field-Weighted Citation Impact
- 4.99